1 Please read immediately
1.1 Important notes
ATTENTION!
!!
Never use cleaning agents containing sand, soda, acid or
chloride, as these can damage the surfaces.
ATTENTION!
!
!
Before opening the device, ensure that all electric circuits are
disconnected from the power supply.
ATTENTION!
!
!
The indoor unit is to be fixed to the transport pallet with
screws.
ATTENTION!
!
!
In an unfilled state (buffer tank and domestic hot water
cylinder without water), the device has a tendency to tilt in the
direction of the hydraulic assembly. Do not lean on the rear of
the unit!
ATTENTION!
!!
With fully demineralized water, it is important to ensure that
the minimum permissible pH value of 7.5 (minimum
permissible value for copper) is complied with. Failure to
comply with this value can result in the heat pump being
destroyed.
ATTENTION!
!
!
Operating the heat pump at low system temperatures may
cause the heat pump to break down completely. After a
prolonged power failure, the commissioning procedure
detailed above must be followed.
ATTENTION!
!
!
Work on the system must only be performed by authorised
and qualified after-sales service technicians!
ATTENTION!
!
!
Incorrect filling with refrigerant could lead to faults during
operation.
ATTENTION!
!!
Never open the valves of the outdoor component. Carry out
the work from Cap. 8.2 on pag. 12 and Cap. 8.3 on pag. 13 first
of all.
The operational reliability of the safety valve must be checked
at regular intervals. We recommend having an annual service
inspection carried out by a qualified specialist company.
The outflow from the safety valve should visibly flow into a
waste water drain.
The installer of the heating system is responsible for checking
whether an additional expansion vessel is required.
Operating the system in a sensible way can provide significant
energy savings. The heating water temperature should be as
low as required during heat pump operation. The planner of the
heating system is responsible for determining the system tem-
perature.
When installing an underfloor heating system, a sensible value
for the maximum flow and return temperature should be set on
the heat pump manager. The position of the temperature sen-
sor is important in this regard.
1.2 Intended use
This device is only intended for use as specified by the manu-
facturer. Any other use beyond that intended by the manufac-
turer is prohibited. This requires the user to abide by the rele-
vant project planning documents. Please refrain from
tampering with or altering the device.
1.3 Legal regulations and guidelines
This heat pump is designed for use in a domestic environment
according to Article 1, Paragraph 2 k) of EU directive 2006/42/
EC (machinery directive) and is thus subject to the require-
ments of EU directive 2014/35/EU (low-voltage directive). It is
thus also intended for use by non-professionals for heating
shops, offices and other similar working environments, agricul-
tural establishments and hotels, guesthouses and other resi-
dential buildings.
The construction and design of the LAW device complies with
all relevant EU directives, DIN and VDE regulations (see CE de-
claration of conformity).
When connecting the LAW device to the power supply, the rel-
evant VDE, EN and IEC standards are to be fulfilled. Any further
connection requirements stipulated by the mains supply net-
work operator must also be observed.
The current valid regulations must be complied with when con-
necting the heating system. The local regulations for the drink-
ing water supply must also be complied with when connecting
the LAW device to the drinking water supply.
This unit can be used by children aged 8 and over and by per-
sons with limited physical, sensory or mental aptitude or lack of
experience and/or knowledge, providing they are supervised or
have been instructed in the safe use of the unit and understand
the associated potential dangers.
Children must not play with the device. Cleaning and user
maintenance must not be carried out by children without su-
pervision.
ATTENTION!
!
!
When operating or maintaining a heat pump, the legal
requirements of the country where the heat pump is operated
apply. Depending on the refrigerant quantity, the heat pump
must be inspected for leaks at regular intervals by a certified
technician, and these inspections must be recorded.
More information can be found in the accompanying log book.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex LAW 9IMR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex LAW 9IMR in the language / languages: English, German, French as an attachment in your email.

The manual is 7.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info