LAK 3IMR - LAK 14ITR English
2Purpose
2.1 Area of application
The indoor unit constitutes the interface between a reversible
heat pump and the heating system in the building. The indoor
unit contains all hydraulic components required between heat
generation and heat distribution with an unmixed heating cir-
cuit.
2.2 General properties
Low installation effort
Ready for use
The infinitely adjustable operation of the circulating pump
permits adjustment of the output according to need.
on LAK 6IMR - LAK 14ITR:
Switchable pipe heater (2 / 4 / 6 kW) for supplementary
heating.
on LAK 3IMR:
with 2 kW (fixed-setpoint) pipe heating
3 Scope of supply
3.1 Indoor unit
Hydraulic components
Unmixed heating circuit including controlled circulating
pump
2nd heat generator, electrical pipe heater, heat output 2 /
4 / 6 kW, secured via safety temperature limiter
Safety equipment:
Safety valve, start-to-leak pressure 2.5 bar
Refrigerating equipment
Heat exchanger refrigerant / heating water
Connections for split line
NOTE
º
ºººº
External sensor is included with the outdoor unit as standard.
Option for connecting an external sensor Cap. 8.5.2 on pag.
16.
3.2 Contact plate
The cover must be removed to allow access to the inside of the
device.
The two screws on the bottom must be loosened for this. The
cover must then be removed to the top.
CAUTION!
!
!
Before opening the device, ensure that all circuits are
disconnected from the power supply!
After removing the cover, the electronics area is freely accessi-
ble.
The contact plate contains the supply connection terminals,
heating contactors, connecting terminals for the connecting
line to the heat pump and the heat pump manager.
3.3 Wärmepumpenmanager
The integrated heat pump manager is a convenient electronic
regulating and control device. It controls and monitors the en-
tire heating system based on the outdoor temperature, as well
as domestic hot water preparation and safety systems.
The enclosed operating instructions describe the functional
principle and use of the heat pump manager.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex LAK 14ITR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex LAK 14ITR in the language / languages: English, German, French as an attachment in your email.

The manual is 7.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info