798322
32
Zoom out
Zoom in
Previous page
1/100
Next page
EN-6 452162.66.09a · FD 0108 www.glendimplex.de
English LAK 3IMR - LAK 14ITR
4.2 Precautions in winter and in
seasonal winds
In snowy areas or extremely cold locations, adequate pro-
tective measures must be taken to guarantee that the unit
continues functioning correctly.
Install the outdoor unit so that snow cannot fall directly on
the unit. If snow collects on the air inlet and freezes, errors
can occur. Install a cover in areas with snowfall.
When installing the outdoor unit in areas where there is a
lot of snowfall, ensure the unit is installed at least as high as
the level of an average snowfall (average annual snowfall).
If more than 100 mm of snow collects on the outdoor unit,
the snow must be removed prior to operation.
NOTE
º
ºººº
The intake and outlet opening of the outdoor unit should not
be positioned against the wind if possible.
5 Assembly indoor unit
5.1 General
The unit should always be installed indoors on a level, smooth
wall. Maintenance work can be carried out easily from the oper-
ator side (a minimum clearance at the side is not required). This
can be ensured by maintaining a clearance of 1 m at the front.
The indoor unit should be mounted at a height of approx.
1.30 m. It must be installed in a room protected from frost and
with short pipe runs.
NOTE
ººººº
Setup and installation must be performed by an authorised
specialist company.
When installing the indoor unit, the load-bearing capacity of the
wall should be checked. On account of the acoustics, measures
for isolating possible vibrations should also be very carefully
planned in advance.
The following connections need to be established on the indoor
unit:
Flow / return of the heating system
Safety valve outflow
Power supply
Supply voltage
Split refrigerant pipe
Condensate drain
Expansion vessel connection (optional)
NOTE
º
ºººº
When removing the unit cover, it must be taken into account
that the length of the connecting cable between the control
panel in the unit cover and the controller on the contact plate
is only 1.5 m. If the device cover can only be placed further
away than this when it has been removed, the plug
connection on the controller or on the control panel must first
be disconnected.
5.2 Indoor unit fixing
The indoor unit is attached to the wall with the screws and dow-
els (8 mm) included in the scope of supply. The following pro-
cedure should be used:
Mount the dowels for the top fastening eyelets.
Screw the screw into the dowel so that the indoor unit can
be mounted.
Mount the indoor unit by the upper fastening eyelets.
Mark the position of the side drill-holes.
Unhook the indoor unit again
Mount the dowels for the side drill holes.
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex LAK 14IMR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex LAK 14IMR in the language / languages: English, German, French as an attachment in your email.

The manual is 7.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info