9.1SCOP (Seasonal coefficient of performance) average climate 35°C / 55°C4.01 / 3.40
9.2ŋs average climate 35°C / 55°C157 / 133
9.3Heat output / coefficient of performance (COP) 810
Heat source / heat sinkEN 14511
Air / waterPerformance level12
with A-15 / W35kW / ---16.9 / 2.631.7 / 2.6
with A-7 / W35kW / ---22.2 / 3.238.0 / 3.0
with A2 / W35kW / ---26.6 / 3.643.4 / 3.4
with A7 / W35-30 kW / ---35.3 / 4.5
with A12 / W35kW / ---38.1 / 4.8
with A7 / W45-40 kW / ---32.9 / 3.7
with A7 / W55-47 kW / ---31.7 / 3.2
9.4Cooling capacity / coefficient of performance (COP) 810
Heat sink / heat sourceEN 14511
Air / waterPerformance level12
with A35 / W23-18kW / ---33.4 / 3.263.3 / 2.8
with A27 / W18kW / ---34.8 / 3.767.8 / 3.5
with A35 / W12-7kW / ---23.1 / 2.548.1 / 2.5
with A27 / W7kW / ---25.2 / 3.051.6 / 3.0
1.For air temperatures between -22°C and 0°C, flow temperature increasing from 45°C to 60°C.
2.The specified maximum heating water flow temperature applies to a set minimum heating water flow.
3.The minimum achievable flow temperature depends on the current volume flow, the set return set temperature and the current performance level.
4.In 2-compressor operation with A35/W7, results in a cooling water temperature difference of 5K ±1K.
5.The heat output and COP is reduced by approx. 5% in lower operation
6.The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 55°C.
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A)depending on the installation location.
7.Note that additional space is required for pipe connections, operation and maintenance
8.This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, the bivalence point and
the regulation should be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for maintenance, commissioning and operation can
be found in the relevant sections of the assembly and operating instructions. The specified values have the following meaning, e.g. A 7 / W35: heat source temperature 7°C and
heating water flow temperature 35°C.
9.The heat circulating pump and the heat pump manager must always be ready for operation.
10.The values specified apply when using the hydraulic four-way reversing valve (observe instructions for accessories).
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Dimplex LA60S TUR at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Dimplex LA60S TUR in the language / languages: English as an attachment in your email.
The manual is 1.53 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.