520386
24
Zoom out
Zoom in
Previous page
1/48
Next page
EN-10 452163.66.23 · FD 9801 www.dimplex.de
English LA 60TU
11 Device information
1 Type and order code LA 60TU
2Design
2.1 Model / controller Universal / external
2.2 Thermal energy metering Integrated
2.3 Installation location / degree of protection according to EN 60529 Outdoor / IP24
2.4 Antifreeze condensate tray / heating water Heated / yes1
1. The heat circulating pump and the heat pump manager must always be ready for operation.
2.5 Performance levels 2
3 Operating limits
3.1 Heating water flow / return2°C
2. At air inlet temperatures of -20 °C to 0 °C flow temperature rising from 55 °C to 65 °C (see operating limits diagram).
up to 65 ± 2 / from 18
Air (heat source) °C -20 to +35
4 Performance data / flow rate
4.1 Heating water flow rate /
internal pressure differential A7/W35/30 m³/h / Pa 10.4 / 8300
A7/W45/38 m³/h / Pa 7.7 / 4500
Minimum heating water flow A7/W55/45 m³/h / Pa 5.3 / 2100
4.2 Heat output / COP 3
3. These data indicate the size and capacity of the system according to EN 255 (10K at A2) and EN 14511 (5K at A7) without weather-proof protective cover. For an analysis of the
economic and energy efficiency of the system, other parameters, in particular the defrosting capacity, the bivalence point and the regulation, should also be taken into consideration.
The specified values have the following meaning, e.g. A7 / W35: External air temperature 7 °C and heating water flow temperature 35 °C.
EN 255 EN 14511
at A-7 / W35 kW / --- 4
4. 2-compressor operating mode
39.3 / 3.0 39.2 / 2.9
kW / --- 5
5. 1-compressor operating mode
21.3 / 3.1 21.2 / 3.0
at A2 / W35 kW / --- 450.0 / 3.7 50.0 / 3.6
kW / --- 526.4 / 3.8 26.4 / 3.7
at A7 / W35 kW / --- 460.1 / 4.1
kW / --- 531.9 / 4.3
at A7 / W55 kW / --- 455.0 / 2.8
kW / --- 528.3 / 2.9
at A10 / W35 kW / --- 466.6 / 4.4 64.6 / 4.2
kW / --- 538.4 / 4.6 33.6 / 4.4
4.3 Sound power level Normal operation / reduced operation dB(A) up to 74 / up to 70
4.4 Sound pressure level at a distance of 10 m (air outlet side) 6
Normal operation / reduced operation dB(A)
6. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
up to 50 / up to 46
4.5 Air flow m³/h 14000
5 Dimensions, connections and weight
5.1 Device dimensions without connections7H x W x L mm
7. Note that additional space is required for pipe connections, operation and maintenance.
2300 x 1900 x 1000
5.2 Device connections for heating system Inches R 2“
5.3 Weight of the transportable unit(s) incl. packaging kg 915
5.4 Refrigerant / total filling weight type / kg R417A / 20,9
5.5 GWP value / CO2 equivalent --- / t 2346 / 49
5.6 Refrigeration circuit hermetically sealed yes
5.7 Lubricant / total filling quantity type / litres Polyolester (POE) / 8.28
6 Electrical connection
6.1 Load voltage / Fuse protection 3~/N/PE 400 V (50 Hz); Z50 A
6.2 Control voltage / Fuse protection ---
6.3 Starting current with soft starter A 78
6.4 Nominal power consumption A2 W35/
max. consumption 3, 4kW 14.9 / 27.6
6.5 Nominal current A2 W35 / cosϕ4 A / --- 29.5 / 0.8
6.6 Max. power consumption of compressor protection
(per compressor) W 70, thermostatically controlled
7 Complies with the European safety regulations 8
8. See CE declaration of conformity
8 Additional model features
Type of defrosting (according to need) Reverse circulation
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex LA 60TU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex LA 60TU in the language / languages: English, German, French as an attachment in your email.

The manual is 3.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dimplex LA 60TU

Dimplex LA 60TU Usermanual and installation guide - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info