1.The heat circulating pump and the heat pump manager must always be ready for operation.
2.See output curves; For air temperatures between -25°C and 0°C, flow temperature increasing from 50°C to 60 °C.
3.Domestic hot water preparation via additional heat exchanger operating in parallel. The waste heat output and/or the attainable cylinder temperature is dependent on the present
operating point (temperature level/performance level). The waste heat output falls when the cylinder temperature rises.
4.This data indicates the size and capacity of the system according to EN 14511 (5K at A7) and/or EN 255 (10K at A2) without weather-proof protective cover. For an analysis of
the economic and energy efficiency of the system, other parameters, in particular the defrosting capacity, the bivalence point and the regulation, should also be taken into consid-
eration. The specified values have the following meaning, e.g. A7 / W35: External air temperature 7 °C and heating water flow temperature 35°C.
5.The specified coefficients of performance are also achieved in parallel hot water preparation via additional heat exchangers.
6.In order to obtain the values specified, the optionally available hydraulic 4-way reversing valve (external) must be used.
Without the reversing valve, the heat output is reduced by approximately 10%, the COPs by approximately 12%.
7.2-compressor operating mode
8.1-compressor operating mode
9.In 2-compressor operating mode at A35/W18 this results in a cooling water temperature spread of 5K ± 1K. Necessary for ensuring waste heat recovery in cooling operation.
10.Considerably higher COPs are achieved by means of cooling operation and waste heat recovery using additional heat exchangers.
11.The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35°C.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Dimplex LA 35TUR plus at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Dimplex LA 35TUR plus in the language / languages: English, German, French as an attachment in your email.
The manual is 3.74 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.