798429
40
Zoom out
Zoom in
Previous page
1/76
Next page
EN-16 452166.66.14 · FD 0008 www.glendimplex.de
English LA 33TPR
9Care
To protect the paintwork, avoid leaning anything against the
device or putting objects on the device. External heat pump
parts can be wiped with a damp cloth and commercially availa-
ble domestic cleaner.
NOTE
º
ºººº
Never use cleaning agents containing sand, soda, acid or
chloride, as these can damage the surfaces.
To prevent faults due to sediment in the heat exchanger of the
heat pump, ensure that the heat exchanger in the heating sys-
tem cannot be contaminated. Should operating malfunctions
due to contamination still occur, however, the system should
be cleaned as described below.
10 Maintenance work
10.1 General
NOTE
º
ºººº
The maintenance instructions must be observed.
Work on the heat pump must only be performed by authorised
and qualified after-sales service technicians!
The device contains combustible refrigerant. Avoid ignition
sources in the safety zone!
Before starting the maintenance, the system log book must be
observed with respect to repairs and modifications already car-
ried out.
Periodic inspections required by law, e.g. German industrial
safety regulations (BetrSichV) etc., must also be observed.
To protect the paintwork, avoid leaning anything against the
device or putting objects on the device. External heat pump
parts can be wiped with a damp cloth and commercially availa-
ble domestic cleaner.
NOTE
º
ºººº
Never use cleaning agents containing sand, soda, acid or
chloride, as these can damage the surfaces.
NOTE
º
ºººº
Only software that is authorised and approved by the
manufacturer can be installed on the machine's control
system.
NOTE
º
ºººº
Only original spare parts may be used.
CAUTION!
!
!
Maintenance and operating instructions for the machine and
the switch box must be taken into account
CAUTION!
!
!
The leakage tightness of the refrigerant circuit must be tested
after all assembly work is complete and the external power
supply (load and control voltage) has been connected.
CAUTION!
!
!
The long-term leakage tightness of the entire hydraulic circuit
must be ensured (for example through repeated inspection).
The device is a permanently technically sealed system. In rare
cases, however, leakages may occur on the plate heat ex-
changer due to freezing. The risk is increased in particular in the
event of tampering on the dirt traps, if the requirements for fill-
ing the hydraulic circuit are not complied with, or if the mini-
mum flows are not observed.
CAUTION!
!
!
Commissioning, maintenance and repair only by personnel
who have verifiably been trained in dealing with the
refrigerant propane.
10.2 Cleaning the heating system
See the maintenance instructions
10.3 Cleaning the air system
See the maintenance instructions
10.4 Maintenance intervals
Maintenance cycle
The standard maintenance interval is 6 months. If operated for
less than 3,000 hours per year and in conjunction with a corre-
sponding remote monitoring system, the maintenance interval
may be extended to 12 months.
See the maintenance instructions
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex LA 33TPR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex LA 33TPR in the language / languages: English, German, French as an attachment in your email.

The manual is 3.6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info