798249
17
Zoom out
Zoom in
Previous page
1/60
Next page
www.dimplex.de 452163.66.10 · FD 9506 EN-3
English
LA 17TU - LA 40TU
1.4 Energy-efficient use of the heat
pump
By operating this heat pump, you are helping to protect the envi-
ronment. A prerequisite for energy-efficient operation is the cor-
rect design of the heat source system and heating system.
It is particularly important for the efficiency of a heat pump to
keep the temperature difference between heating water and heat
source as small as possible. For this reason, it is advisable to de-
sign the heat source and heating system very carefully. A tem-
perature difference of approx. one Kelvin (one °C) increases
the power consumption by around 2.5 %. When designing the
heating system, it should be borne in mind that special consu-
mers such as e.g. domestic hot water preparation should also be
taken into consideration and dimensioned for low temperatures.
Underfloor heating systems (panel heating) are optimally sui-
ted for heat pump use on account of the low flow temperatures
(30 °C to 40 °C).
It is important to ensure that the heat exchangers are not conta-
minated during operation because this increases the tempera-
ture difference, in turn reducing the COP.
Correct adjustment of the heat pump manager is also important
for energy-efficient use of the heat pump. Further information can
be found in the operating instructions of the heat pump manager.
2 Purpose of the heat
pump
2.1 Application
The air-to-water heat pump is to be used exclusively for the hea-
ting of heating water. It can be used in new or already-existing
heating systems.
The heat pump is suitable for mono-energy and bivalent opera-
tion down to an external temperature of -25 °C.
Proper defrosting of the evaporator is guaranteed by maintaining
a heating water return temperature of more than 18 °C during
continuous operation.
The heat pump is not designed for the increased heat consump-
tion required when a building is being dried out. For this reason,
the additional heat consumption should be met using special de-
vices provided by the customer. If a building is to be dried out in
autumn or winter, we recommend installing an additional electric
heating element (available as an accessory).
NOTE
The device is not suitable for operation with a frequency converter.
2.2 Operating principle
Surrounding air is drawn in by the fan and fed through the evapo-
rator (heat exchanger). The evaporator cools the air, i.e. it ex-
tracts heat from it. This extracted heat is then transferred to the
working medium (refrigerant) in the evaporator.
The heat is brought to a higher temperature level by increasing
its pressure with the aid of the electrically driven compressor. It is
then transferred to the heating water via the liquefier (heat ex-
changer).
Electrical energy is used to raise the temperature of the heat in
the environment to a higher level. As the energy extracted from
the air is transferred to the heating water, this type of device is
called an air-to-water heat pump.
The air-to-water heat pump consists of the main components:
evaporator, ventilator and expansion valve, as well as the low-
noise compressors, the liquefier and the electrical control sys-
tem.
At low ambient temperatures, humidity accumulates on the eva-
porator in the form of frost, reducing the transfer of heat. Uneven
accumulation during this process does not indicate a fault. The
evaporator is defrosted automatically by the heat pump as re-
quired. Steam may be emitted from the air outlet depending on
the atmospheric conditions.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex LA 25TU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex LA 25TU in the language / languages: English, German, French as an attachment in your email.

The manual is 5.06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info