INSTALLATION MANUAL
Ø
Use the fire's dimensional sketch to see which fire pipe diameter you need (see Annex 1, table 2).
Ø
Use a fire pipe that at least meets the requirements of standards as established in EN 1856-2 T600.
Ø
Install the flue pipes in such a way that a fire hazard can never originate.
Ø
When installing a free-standing fire take account of the minimum required distance from the fire to a
non-flammable wall. This distance amounts to 50 mm.
Ø
When installing the fire and/or flue pipes respect the minimum distance to flammable objects and materials as
shown in Annex 1, table 2.
Ø
Take adequate measures to avoid too high temperatures in any walls behind the chimney breast.
This also applies for materials and/or objects behind the wall.
Ø
Respect the flue duct requirements as described in paragraph. 5.2.
For any appliance-specific instructions we refer to section 9 'Appliance-specific information'.
!CAUTION
If you are installing a built-in appliance take account of:
- The minimum building-in dimensions according to Annex 2, Fig. 1.
5.4.1 Free-standing/design fires
5.4.1.1 Conversion from fire top connection to rear connection (if applicable).
The fire is supplied with a top connection for connecting the flue duct.
The top connection can be converted to a rear connection.
To do this proceed as follows (see Annex 2, Fig. 2):
Ø
Take the flame baffle plate or baffle plates out of the fireplace (if applicable see section 9, 'Appliance-specific
information').
Ø
Your appliance can be provided with an extra steel restrictor cap (if applicable see section 9, 'Appliance-specific
information'). Remove this by sliding the restrictor cap forwards and taking it out of the rails. This restrictor cap is
not replaced with a rear connection.
Ø
Remove the fire's convection back plate by undoing the bolts.
Ø
Remove the push-through plate from the convection back plate.
Ø
Remove the cover plate for the flue from the back wall of the fire by undoing the 2 or 3 nuts.
Ø
Remove the flue ring from the top plate by undoing the nuts and/or bolts.
Ø
Fit the flue ring on the back wall using the bolts and/or nuts.
Ø
Fasten the convection back plate again with the bolts.
Ø
Assemble the cover plate for the flue in the opening in the top plate using the nuts.
Ø
Replace the flame baffle plate or baffle plates in the reverse order.
5.4.1.2 Installing a free-standing fire, general
A free-standing fire is installed as follows:
Ø
Determine the fire location. The dimensions of the appliance are given in Annex 2, Fig. 1.
Ø
For any appliance-specific instructions we refer to section 9 'Appliance-specific information'.
Ø
Make sure there are no flammable materials present.
Ø
Lay the floor plate if applicable.
Ø
Place the fire on a blanket or sheet of cardboard (to avoid damaging the floor) then put it in the desired place.
Ø
Connect the fire to the flue duct. Follow the instructions of the supplier of the flue gas extraction system. Use
heater piping material that at least suffices with regard to EN 1856-2 T600.
Ø
Lift the fire a little if necessary so the blanket or cardboard can be removed.
Ø
For completing installation we refer to paragraph 5.5.
5.4.1.3 Design fire installation
To install a design fire we refer to Section 9 'Appliance-specific information'.
UK
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dik Geurts Prostyle 600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dik Geurts Prostyle 600 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dik Geurts Prostyle 600

Dik Geurts Prostyle 600 User Manual - English, German, Dutch, French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info