2.3 The Clean Air Act 1993 and Smoke Control Areas
2.3.1 Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke
control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if
located in a designated smoke control area. It is also an offence to acquire an "unauthorised fuel" for use within a
smoke control area unless it is used in an "exempt" appliance ("exempted" from the controls which generally apply
in the smoke control area).
In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes
made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015. Similarly in
Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory
Reform (Scotland) Act 2014.
In Wales and Northern Ireland these are authorised by regulations made by Welsh Ministers and by the Department
of the Environment respectively.
Further information on the requirements of the Clean Air Act can be found here:
https://www.gov.uk/smoke-control-area-rules
Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision
of smoke control areas and you can contact them for details of Clean Air Act requirements.
The following Dik Geurts wood burning stoves have been recommended as suitable for use in smoke control areas
when burning wood logs.
Aste 5, Low • Vidar Triple Small
Bora Corner • Vidar Triple Small, Store
Instyle 500 /550 /600 /650 and 700 • Vidar Triple Medium
Instyle Corner Slim 660/495 • Vidar Triple Medium, Store
Instyle Corner Slim 660/570 • Vidar Triple Large
Ivar 5-01, Low /Ivar 5, High and Ivar 5, Store • Vidar Triple Large, Store
Ivar 8, Store / Ivar 8, Low • Folke
Jannik Medium, Low • Soren 5
Keld 5-01, Low and Keld 5, High • Oval Front
Modivar 5 • Oval Tunnel
Odin Front • Instyle Triple 660 low-01
Prostyle 500 / 550 / 600 / 650 and 700
The Ivar 8, Store and Ivar 8, Low wood burning stove must be fitted with a permanent stop to prevent closure of the
primary air control beyond the 6.0cm open position.
The Bora Corner L must be fitted with a permanent stop to prevent closure of the primary air control beyond the
18.3cm open position.
The Bora Corner R must be fitted with a permanent stop to prevent closure of the primary air control beyond the
20.3cm open position.
The Vidar Triple Small (Store) must be fitted with a permanent stop to prevent closure of the secondary air control
beyond 14mm open.
Instyle Triple 660 Low-01 & Vidar Triple Medium (Store) must be fitted with a permanent stop to prevent closure of
the secondary air control beyond 16mm open.
The Vidar Triple Large (Store) must be fitted with a permanent stop to prevent closure of the secondary air control
beyond 15mm open.
The Folke must be fitted with a permanent stop to prevent closure of the secondary air control beyond 7mm open.
Exemption details can be found at: https://smokecontrol.defra.gov.uk/appliances.php
Further information on the requirements of the Clean Air Act can be found here:
https://www.gov.uk/smoke-control-area-rules
2.3.2 Exempt appliances
Exempt appliances are appliances (ovens, wood burners and stoves) which have been exempted by Statutory
Instruments (Orders) under the Clean Air Act 1993 or Clean Air (Northern Ireland) Order 1981. These have passed
tests to confirm that they are capable of burning an unauthorised or inherently smoky solid fuel without emitting
smoke.
Appliances which are authorized for use in Smoke Control Areas: http://smokecontrol.defra.gov.uk/appliances.php
UK
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dik Geurts Ivar 10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dik Geurts Ivar 10 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 12.44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dik Geurts Ivar 10

Dik Geurts Ivar 10 Installation Guide - English, German, Dutch, French - 96 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info