8. HARDWARE SETTING
8.1 Main Board Jumper Setting
Below is Main Board jumper setting for SM500MK4 using 300 LCD, If the jumper setting wrongly to set, the
display will not function/working properly.
Both LCD (Operator and Customer) are using 300LCD, then follow the below table
Type of LCD JP4 JP5
300LCD Short 2 & 3 Short 2 & 3
Note: This setting is Default Setting for SM500MK4 Main Board.
9. MISCELLANEOUS
9.1 Error Messages
Error No. Error Message Causes
0
PRINTER CASSETTE OPEN
Cassette not inserts properly. Re-insert cassette again.
1
PAPER END Label sensor sense no label. No more labels. Replace label roll.
2
PLEASE PRESS FEED KEY Label miss feed, press FEED key to align label.
3
PLEASE PEEL LABEL Peel sensor activated, remove label away from sensor.
4
CHANGE LABEL SWITCH Remove cassette and set cassette switch to Label.
5
CHANGE RECEIPT SWITCH Remove cassette and set cassette switch to Receipt.
6
NON PRINT No manual printing.
7
UNIT PRICE OVERFLOW Please check unit price
8
TOTAL PRICE OVERFLOW Accumulated total price is overflow, check unit price.
9
NON LABEL No free format is programs. Set a free format or use standard format.
10
INSUFFICIENT SPACE Not enough printing place.
11
NON ADVERTISEMENT No such advertisement data or number exists.
12
READ FILE Read file errors. Memory problem. Please clear the memory.
13
NON SHOP NAME No such shop name data or number exists.
14
PRINTER HEAD NO CLOSE Thermal head no closed. Please close thermal head.
15
WRITE FILE Write file errors. Memory problem. Please clear the memory
16
NO MEMORY Not enough memory. Expand memory or delete unnecessary data.
17
FILE DELETE ERROR Delete file errors. Memory problem.
18
PLEASE REMOVE WEIGHT Fixed price item, please remove weigh.
19
PLU NOT EXIST No such PLU data or number exists.
20
TOTAL PRICE = 0 No total price for item. Unit price or weight is 0.
21
WEIGH ITEM Multiplication key cannot use for weigh PLU.
22
CANNOT USE IN PRE-PACK Accumulation is not allowed in Pre-pack mode.
23
PRESET KEY NOT SET Preset key does not have any preset function or PLU.
24
WEIGHT OVERFLOW Weight over maximum capacity when print.
25
NEGATIVE TOTAL PRICE After discount, total price is negative. Check discount setting.
26
TOTAL PRICE OVERFLOW Total price over the limit to display or print.
27
ILLEGAL OPERATION Operation procedure is incorrectly, please check procedure.
28
QUANTITY = 0 Cannot print when quantity is 0. Please enter a quantity value.
29
PLEASE SET TARE VALUE When force tare is enabling, a tare weight must be entered.
30
KEY INVALID Key pressed had no function or invalid in certain function.
31
NUMBER INVALID Only input number or number input is not in the function.
32
EXCEED MAX LIMIT Max. Number of characters reach.
33
SIZE INVALID No such character size exists. Check the downloaded files.
34
MAIN GROUP NOT EXIST No such Main Group data or number exists.
35
PLU INVALID No such PLU data when copy PLU.
49


Need help? Post your question in this forum.

Forumrules
1

Forum

digi-sm-500mk4

Reset search

  • como cambio tamaño de letra en la etiqueta de balanza digi sm 5oo
    Submitted on 26-7-2023 at 22:10

    Reply Report abuse
  • How to initialise network the scale is not working Submitted on 30-5-2023 at 08:46

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Digi SM-500MK4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Digi SM-500MK4 in the language / languages: English as an attachment in your email.

The manual is 2,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info