GB Checking Accuracy –
Vertical Beam (See Figure 9)
Checking the vertical (plumb) calibration of the laser can be
most accurately done when there is a substantial amount of
vertical height available, ideally 30’ (9m), with one person on
the oor positioning the laser and another person near a ceiling
to mark the position of the beam. It is important to conduct
a calibration check using a distance no shorter than the distance
of the applications for which the tool will be used.
1. Place the laser on a smooth, at, stable surface that is level
in both directions and turn on both vertical beams (Figure
9 #1).
2. Mark two short lines where the beams cross ( a, b) and
also on the ceiling c, d. Always mark the center of the
beams’ thickness (Figure 9 #2).
3. Pick up and rotate the laser 180 º, and position it so the
beams line up with the marked lines on the level surface
(e, f) (Figure 9 #3).
4. Mark two short lines where the beams cross on the
ceiling g, h.
5. Measure the distance between each set of marked lines
on the ceiling ( c, g and d, h). If the measurement
is greater than the values shown below, the laser must be
serviced at an authorized service center.
Ceiling Height
Allowable Distance
Between Marked Lines
2.5 m (8’) 1.5 mm (1/16”)
3 m (10’) 2.0 mm (3/32”)
4 m (14’) 2.5 mm (1/8”)
6 m (20’) 4 mm (5/32”)
9 m (30’) 6 mm (1/4”)
Checking 90º Accuracy Between Vertical Beams
(DCE089R/G) (See Figure 10 )
Checking 90º accuracy requires an open oor area at least 10m
x 5m (33’ x 18’). Refer to Figure 10 for the position of the laser
at each step and for the location of the marks made at each
step. Always mark the center of the beams’ thickness.
1. Set up the laser on a smooth, at, stable surface that is level
in both directions and turn on the side vertical beam.
2. Mark the center of the beam at three locations
(a, b, c) along the side laser line. Mark b should be at
the midpoint of the laser line (Figure 10 #1).
3. Move the laser to mark b and turn on both vertical beams
(Figure 10 #2).
4. Position the beam crossing precisely at mark b, with the
side beam aligned with mark a.
5. Mark a location e along the front vertical beam at least 4m
(14’) away from the unit.
6. Rotate the laser cross over mark b so that the beams pass
through marks b and e (Figure 10 #3).
7. Mark the center of the beam f directly above or below a.
8. Measure the distance between marks a and f. If the
measurement is greater than the values shown below, the
laser must be serviced at an authorized service center.
Distance from a to b
Allowable Distance
Between a & f
4 m (14’) 3.5 mm (5/32”)
5 m (17’) 4.5 mm (3/16”)
6 m (20’) 5.5 mm (7/32”)
7 m (23’) 6 mm (1/4”)
Troubleshooting
The Laser Does Not Turn On
Make sure AA batteries (when used) are installed correctly
according to (+) and (–) on the inside of the battery door.
Make sure the batteries or rechargeable pack are in proper
working condition. If in doubt, try installing new batteries.
Make sure that the battery contacts are clean and free of
rust or corrosion. Be sure to keep the laser level dry and use
only new, high-quality, name brand batteries to reduce the
chance of battery leakage.
If the laser unit is heated above 50 ˚C (120 ˚F), the unit will
not turn on. If the laser has been stored in extremely hot
temperatures, allow it to cool. The laser level will not be
damaged by pressing the on/off button before cooling to its
proper operating temperature.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DeWalt DCE0811R at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DeWalt DCE0811R in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 3.67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info