ENGLISH
Your DEWALT charger is double
insulated in accordance with EN 60335.
Mains plug replacement
(U.K. & Ireland only)
Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
DEWALT repair agent or a qualified electrician.
Disconnect the plug from the supply.
Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (4).
Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminal screws.
Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or .
Using an extension cable
An extension cord should not be used unless
absolutely necessary. Use an approved extension
cable suitable for the power input of your charger
(see technical data).
The minimum conductor size is 1 mm
2
;
the maximum length is 30 m.
Assembly and adjustment
Prior to assembly and adjustment,
always remove the battery pack.
Always switch off the tool before
inserting or removing the battery pack.
Use only DEWALT battery packs and
chargers.
Battery pack (fig. A & B)
Charging the battery pack
To charge the battery pack (9), insert it into the
charger (11) as shown and plug in the charger.
Be sure that the battery pack is fully seated in the
charger, but do not force it.
The red charging indicator (12) will blink. After
approx. 1 hour, it will stop blinking and remain on.
The battery pack is now fully charged and the
charger automatically switches to equalisation mode.
After approx. 4 hours, it will switch to maintenance
charge mode. The battery pack can be removed at
any time or left in the connected charger indefinitely.
The red charging indicator flashes rapidly to
indicate a charging problem. Reinsert the battery
pack or try a new one. If the new pack also
refuses to charge, have your charger tested by
an authorised DEWALT repair agent.
When plugged into power sources such as
generators or sources that convert DC to AC,
the red charging indicator may blink twice, switch
off and repeat. This indicates a temporary
problem of the power source. The charger will
automatically switch back to normal operation.
Do not charge the battery pack at
ambient temperatures < 4 °C or > 40 °C.
Recommended charging temperature:
approx. 24 °C.
Inserting and removing the battery pack
Insert the battery pack into the grip (8) until it
clicks in place.
To remove the battery pack, press the two
release buttons (10) simultaneously and pull the
pack out of the grip (8).
Battery cap (fig. B)
A protective cap is supplied to cover the contacts of
a detached battery pack. Without the protective cap
in place, loose metal objects could short circuit the
contacts, causing a fire hazard and damaging the
battery pack.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DeWalt DC757 T 10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DeWalt DC757 T 10 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Spanish, Norwegian as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DeWalt DC757 T 10

DeWalt DC757 T 10 Additional guide - English - 20 pages

DeWalt DC757 T 10 Additional guide - Polish - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info