Gas system
8
75Caravan - 10-13 - EN
8Gas system
Chapter overview
This chapter contains instructions regarding the gas system of the vehicle.
The instructions address the following topics:
z safety
z gas consumption
z changing the gas bottles
z gas isolator taps
z external gas connection
z automatic switching facility
The operation of the gas operation appliances of the vehicle is described in
Chapter 10.
8.1 General
X Before starting the journey, when leaving the vehicle or when gas equip-
ment is not in use, close all gas isolator taps and the main isolator tap on the
gas bottle.
X No appliance (e.g. heating or refrigerator) that is operated with an open
flame may be operational while fuel is being filled up, on ferries or in the
garage. Danger of explosion!
X If an appliance is operated with an open flame, do not start the appliance up
in closed areas (e.g. garages). Danger of poisoning and suffocation!
X Have the gas system serviced, repaired or altered by an authorised workshop
only.
X Have the gas system checked by an authorised specialist workshop before
starting up and according to the national regulations. This also applies for
not registered vehicles. For modifications to the gas system have the gas
system immediately checked by an authorised specialist workshop.
X The gas pressure regulator and the exhaust gas pipes also have to be
checked. The gas pressure regulator has to be replaced at least every
10 years. The vehicle owner is responsible for seeing that this is carried out.
X In case of a defect of the gas system (gas odour, high gas consumption) there
is danger of explosion! Close the regulator tap on the gas bottle immediately.
Open doors and windows and ventilate well.
X In case of a defect in the gas system: Do not smoke; do not ignite any open
flames, and do not operate electric switches (light switches etc.).
X Before using the cooker make sure that there is sufficient ventilation. Open
windows or the skylight.
X Do not use the gas cooker or gas oven for heating purposes.
X If there are several gas devices, each gas device must have its own gas iso-
lator tap. If individual gas devices are not in use, close the respective gas iso-
lator tap.
X Ignition safety valves must close within 1 minute after the gas flame has
extinguished. A clicking sound is audible. Check function from time to time.
X The installed gas appliances are designed for use solely with propane or
butane gas or a mixture of both. The gas pressure regulator as well as all
installed gas devices are set for a gas pressure of 30 mbar.
X Propane gas is capable of gasification up to -42 °C, whereas butane gas gas-
ifies at 0 °C. Below these temperatures no gas pressure is available. Butane
gas is unsuitable for use in winter.
77


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dethleffs 2014 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dethleffs 2014 in the language / languages: English as an attachment in your email.

The manual is 4,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dethleffs 2014

Dethleffs 2014 User Manual - German - 230 pages

Dethleffs 2014 User Manual - Dutch - 226 pages

Dethleffs 2014 User Manual - French - 234 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info