64195
18
Zoom out
Zoom in
Previous page
1/146
Next page
13
Easy Setup and Operation Easy Setup and Operation
ENGLISH
ENGLISH
Measures
Cause
Screen example
Store:
Store the checked measurement values.
All parameters are stored.
3
If the check ends, press the ENTER button again.
4
Press the CURSOR
DD
or
HH
button to select
whether or not to save the data you have
checked.
5
Press the CURSOR
FF
button.
After the data is stored, the “Auto Setup / Room EQ”
menu screen appears automatically.
Cancel:
Cancel the auto setup settings.
When measurements have been made using the measurement
microphone, speakers with a built-in filter such as subwoofers
might be set with a value that differs from the physical distance
because of the internal electrical delay.
NOTE:
Do not turn off the power while the data is being stored.
If the power is turned off while the data is being stored, the
Room EQ parameters stored in the memory will be cleared,
and it will not be possible to select “Audyssey”, “Front” or
“Flat” equalizer settings.
q The speakers required for producing suitable
reproduction have not been detected.
The front L and front R speakers were not properly
detected.
Only one channel of the surround (A) and surround (B)
speakers was detected.
Sound was output from the R channel when only one
surround back speaker was connected.
The surround back or the surround (B) speaker was
detected, but the surround (A) speaker was not
detected.
If multiple errors occur, press the CURSOR
FF
or
GG
button
to check the contents.
Check that the pertinent speakers are properly
connected.
w The speaker polarity is connected in reverse.
If multiple errors occur, press the CURSOR
FF
or
GG
button
to check the contents.
Check the polarity of the pertinent speakers.
For some speakers, the screen below may be
displayed even though the speakers are
properly connected.
If so, select “Skip
0
”.
e There is too much ambient noise in the room and the
measurements cannot be made accurately.
r The sound level that is output from the speakers and/or
subwoofer is too low.
Either turn off the power of the device that
generated the noise during the measurements
or move the device away.
•Try again at a time when it is quieter.
Check the placement and orientation of the
loudspeakers.
Adjust the subwoofer’s output level.
t The measurement microphone is not connected, or all
of speakers have not been detected.
Connect the measurement microphone to the
microphone connector.
Check the speaker connection.
Playing a DVD with surround sound
1
Disconnect the microphone from the unit.
2
Select the input source to be played.
4
5
Adjust the volume.
Start DVD playback.
About the error message
These error messages will be displayed when performing the measurements of Auto Setup and the automatic measurements can
not be completed because of the speaker arrangement, measurement environment, or other factors. Please check the following
matters, reset the pertinent items, and measure again. Be sure to turn off the AVR-4306’s power before checking the speaker
connections.
3
Select the play (surround) mode.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Denon AVR-4306 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Denon AVR-4306 in the language / languages: English as an attachment in your email.

The manual is 11,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Denon AVR-4306

Denon AVR-4306 User Manual - German - 146 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info