ENGLISH
Setting up
Rapid couplings in model F300
In this model, the connections of the internal
unit must be disconnected as follows:
1) Unplug the appliance from the main.
2) Remove the filters on the side.
3) Remove the rear door in the back panel
by undoing the two screws.
4) Remove the metal “U”-stays fixing the
pipes to the appliance (2).
5) Use a number 24 spanner to undue the
rotating union on the coupling. At the
same time, use a number 21 spanner to
hold the end of the flexible pipe. Repeat
for the second union using a number 24
and a number 19 spanner
6) Disconnect the condensate pipe from the
pipe fitting.
7) Remove the electrical connection block.
Avoid tight curves in the connection
sheath
Reconnecting the sheath in models F400 and F300
To reconnect the ends of the connecting
sheath to the internal unit, repeat operations
1, 2, 3, 4, 5, 6 and 7 in reverse order, observing
the following precautions:
Before passing the sheath through the
hole in the wall, protect the threaded
ends of the rapid couplings with insulating
tape or similar.
Fit the top two refrigerant couplings to the
bottom two and hand tighten them for
several turns. Check they fit well before
tightening with the spanners used previou-
sly
After connecting the two refrigerant cou-
plings, fix the stays.
Check the seal of the refrigerant connec-
tions by covering the joins with a little
soapy water. No soap bubbles should
form.
Attention
We recommend that disconnection and con-
nection of the rapid couplings be carried out
by qualified personnel.
I 8-08-2001 9:30 Pagina 21
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DeLonghi pac f400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DeLonghi pac f400 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 2,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info