20
USING THE RAPID COUPLINGS
(models F400 and F300 only)
As an alternative to the methods described
above, the sheath connecting the external
and internal units can be passed through a 6
cm diameter hole in a wall communicating
with the outside.
Setting up
NB: Leave at least 30 cm between the wall
and the appliance.
b) Through a small crack (5.5 cm x 2.5 cm) in
the bottom of a door or the frame of a
window, using the sheath frame pro-
vided.
20
PREPARING THE INTERNAL UNIT
Install the appliance inside the room to be air
conditioned, usually near a window or a peri-
meter wall. The internal unit must be located
on the level. Also use the wheel blocks
supplied. The intake zone (intake grill and
emission zone (outlet grill ) of the internal
unit should be kept clear of obstacles.
2
8
22
POSITIONING THE CONNECTING SHEATH
The sheath connecting the external and
internal units can be passed:
a) Through the crack of a window or door left
ajar. Use the suckers to prevent it from
opening further.
21
4
SHEATH CLIP
ELECTRICAL
CONNECTION
BLOCK GUARD
“U”-STAY
1) Unplug the appliance from the main.
2) Remove the handle by undoing the two
metric screws then remove the front panel.
3) Remove the “U”-stay by undoing the two
metric screws.
4) Remove the sheath clip by undoing the
two metric screws.
5) Use a number 24 spanner to undo the
rotating union on the coupling. At the
same time, use a number 21 spanner to
hold the end of the flexible pipe steady.
Repeat for the second union using a num-
ber 24 and a number 19 spanner.
6) Disconnect the condensate pipe from the
pipe fitting.
7) Undo the two self-tapping screws holding
the guard and remove the electrical con-
nection block.
Avoid tight curves in the connection sheath
Rapid couplings in the model F400
In this model, the connections of the external
unit must be disconnected as follows:
I 8-08-2001 9:30 Pagina 20