555818
6
Zoom out
Zoom in
Previous page
1/64
Next page
6
GB
!IF IN DOUBT CONSULT
A QUALIFIED ELECTRICIAN!
All electrical connections e.g. extension cable, must
be of an approved waterproof type for outdoor use.
Exten sion cables must be three-core, one of which is
EARTH.
Always fully unwind extension cables before use.
Connection to the mains power supply must be via an
approved residual current device (RCD), with a residu-
al operating current not exceeding 30mA.
MAINTENANCE
There are no user serviceable parts in this appli-
ance. If the appliance appears to be blocked, switch
off the power at the mains, remove the plug from the
socket and check the appliance for blockages (see
‘Blockages’).
BLOCKAGES
If you suspect the pump has become blocked, switch
off the power at the mains socket remove the plug and
exa mine the turbine. The turbine can be accessed by
remo ving the securing screws in the base and/or sub
base. Alternately try reaching the suspected blockage
through the outlet pipe in the side of the pump.
Always ush through with clean water after every use.
IMPORTANT: During maintenance or cleaning never
rest the appliance of the on the turbine (impeller).
GENERAL USE
This pump is NOT designed for continuous opera-
tion e.g. as a swimming pool or pond circulation
pump.
If used as an intermittent pump to circulate water
in an ornamental pond it must be sited in a sump
or behind a suitable barrier to stop pond life being
suc ked into it.
Use a rope to lower the pump into deep water -nev-
er lower the pump by its power cord or delivery pipe
at anytime.
Ensure there are no obstructions around the inlet
openings around the base of the pump. The inlet
ope nings must be clear of mud or sludge at the bot-
tom of a pool.
It would be advisable to stand the pump of a solid
plat form at the bottom of the pool to keep it upright,
if practical to do so.
If the pump is used to drain a swimming pool it must
only be used when the pool is completely empty of
people.
It is important that the oating switch is allowed to
reach its ON height in the water. It must also be
able to oat down without obstruction in order for it
to switch off when required.
After use allow the pump to run using clean water
for 2-3 minutes in order to remove residues and
parti cles that may have accumulated in the pump
and out let hose.
NOTE:
If the level of water becomes to low, any sludge in the
shaft will dry out more quickly and this may prevent
the pump from restarting. To ensure the pump works
ef ciently the bottom of the shaft must be kept free of
sludge as far as possible and cleaned on a regular ba-
sis when not in use.
OPERATING INSTRUCTIONS
Automatic Operation
When the pump is lowered into the water and the pow-
er is switched on, it will start to operate as soon as the
o ating switch reaches the minimum activation height
in the water.
Remember: The pump must be carried by, and placed
in the water using the carry handle or if the water is
deep, be lowered on a rope tied to the carry handle.
Manual Operation
Where manual operation is preferred, the motor can be
activated by raising the oating switch by hand (ON) or
lowering it by hand (OFF).
Ensure the distance between the oat switch and the
latch holder is not too small as to restrict the up and
down movement of the oat switch.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Defort DSP-400CN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Defort DSP-400CN in the language / languages: All languages as an attachment in your email.

The manual is 2,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info