GB
Electricity
Do not touch the generator if you have wet hands.
Do not operate the generator in wet conditions.
Do not operate the generator near water.
Never connect two generators together.
Never connect the generator to any commercial power
outlet.
Make sure any extension cords used are in a safe con-
dition and of suf cient capacity for the task.
Ensure that the load on the generator falls within its
capacity as speci ed in the table before plugging in any
cords.
To prevent an electric shock, make sure to ground
the generator. Connect a piece of cable between the
ground terminal on the generator and an external
ground point.
Fire and burn hazards
The exhaust system gets hot enough to ignite some
materials:
- keep the generator at least 1 meter away from build-
ings and other equipment during operation.
- keep  ammable materials away from the generator.
The exhaust becomes very hot during operations and
remains hot for a while after stopping the engine:
- Let the engine cool before storing the generator in-
doors.
- Do not touch the hot exhaust with your hands.
Gasoline is extremely  ammable and is explosive un-
der certain conditions. Do not smoke or allow  ames or
sparks where the generator is refueled or where gaso-
line is stored.
Fuel vapors are extremely  ammable and may ignite
after the engine has started. Make sure that any spilled
fuel has been wiped up before starting the generator.
3. USE
BEFORE STARTING THE GENERATOR
Fill and check fuel level 2
Important. Only use a two-stroke mixture, in other words
unleaded petrol (octane level 92 and more) and two-stroke
oil mixed at a ratio of 50:1 (2%) to fuel the generator.
Remove any power cords
Turn power switches off
Do not over ll – leave air gap at top of fuel level
Always screw down fuel cap
Clean up any spilled fuel
Do not smoke while operating the generator
Always use caution!
Starting the generator 1
1. Turn on fuel tap (10).
2. Turn on engine switch (2).
3. Move choke lever (3) to closed position (to restart a
warm engine, leave the choke lever in open or half-
open position).
4. Pull slowly on the starter cord until it engages, then pull
sharply to start the engine (4).
5. Allow the engine to run until it warms up, and then move
the choke lever to the open position (3).
6. Plug in the power cord.
Stopping the generator 1
1. Unplug all cords
2. Turn engine switch to «OFF» (2)
3. Turn off fuel tap (10)
The generator is equipped with DC output (12 V / 5 A) that
allows to charge batteries through the cable supplied. Ob-
serve polarity (red lead to +, black lead to -).
4. SERVICE & MAINTENANCE
PERIODIC MAINTENANCE
Daily (pre-operation check)
Check choke operation
Check recoil starter operation
3 Months or 50 hrs
Check condition of spark plug. Adjust gap and clean.
Replace if necessary.
Clean, replace if necessary.
6 Months or 100 hrs
Clean fuel tap and fuel tank  lter. Replace if neces-
sary.
Check  ttings and fasteners. Replace if necessary.
SERVICE – NOTES ON MAINTENANCE
Spark plug inspection 3
Disconnect the spark plug cap, and remove any dirt
from around the spark plug area.
Remove spark plug (11) with the plug spanner sup-
plied.
Inspect the spark plug. It should be a tan colour.
Measure the gap (distance contact point) with a suit-
able gauge. The gap should be 0.7-0.8 mm. Correct
the gap, if necessary, by carefully bending the side
electrode.
Replace the spark plug if the electrodes are worn, or if
the insulator is cracked or chipped.
Install the spark plug carefully, by hand, to avoid cross-
threading.
Place the spark plug with correct torque: 20 Nm.
Attach the spark plug cap.
Exhaust screen
Wait for exhaust to cool.
Exhaust screen (9) may be blocked up with carbon de-
posits.
Undo the screw cap and remove the exhaust screen.
Clean the screen with a wire brush and re t.
Replace exhaust screen if damaged.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Defort DGI-800 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Defort DGI-800 in the language / languages: All languages as an attachment in your email.

The manual is 2,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info