555768
5
Zoom out
Zoom in
Previous page
1/52
Next page
5
GB
In ation of balls and toys
Install the valve adapter (connector or needle for ball
in ation) on the nipple and latch the lock by pushing
the lever down.
Connect the air hose with the adapter to the in ated
object.
Connect the compressor to the car lighter socket.
Turn the compressor on.
• When the required pressure level is reached, dis-
connect the compressor from the car lighter socket.
Disconnect the air hose with the adapter from the
in ated object.
Quickly close the air passage of the in ated object.
ATTENTION! Control air pressure in the in ated ob-
ject. Avoid excessive pressurization of the in ated
object.
Troubleshooting guide
1. The compressor is not started on
Blown-out fuse in the car
- Replace the blown-out fuse in the fuse box of the
car.
Poor contact in the lighter socket
- Clean the lighter socket with a non-metal object.
2. The compressor is working poorly
The car accumulator is discharged
- Start the car.
Poor contact in the lighter socket
- Clean the lighter socket with a non-metal object.
Cleaning
Every time after completion of work, it is recommended
to clean the body of the car compressor and its air in-
lets from dirt and dust with a cotton cloth or a napkin.
Persistent impurities must be removed with a cloth
soaked in soapy water.
It is prohibited to use solvents: alcohol, ammonia solu-
tions, etc. for dirt removal. These uids adversely affect
plastic parts of the compressor.
To prevent failures
Keep the compressor adapter clean. With the com-
pressor connected to the car cigarette lighter, in
case of short circuit, a life-threatening situation may
occur. Accumulator capacity is very high, so you can
get injured.
Protect the compressor from overheating. Do not
cover the compressor with foreign objects while in
use.
Before connecting, please check
If the adapter and the car lighter socket match;
If the car accumulator voltage matches with the
compressor's characteristics;
If the accumulator can provide 10 A;
Absence of failures and breakdowns in the cable
and the adapter for the cigarette lighter.
OPERATION
First, check pressure in the in ated object. It can be
done with the manometer, installed in the compressor.
Just connect the hose of the idle compressor to the
in ated object.
Avoid excessive pressurization.
Do not place the working compressor in the car com-
partment.
Do not leave the working compressor unattended.
Switch off the compressor immediately in the following
cases:
1. If the adapter or power cable is damaged;
2. Smell of burning insulation appears.
ATTENTION! This compressor is intended for short-
time operation (not more than 10 minutes). Longer
operation of the compressor may cause its overheat-
ing and breakdown. If you need to use the compressor
longer, after rst 10 minutes switch off the device and
let it cool down for 10 minutes before restart.
WARNING! The valve cover shown on the
2 be-
comes very hot during operation. Do not touch this
cover to avoid risk of burns!
In ation of car tires
Place the car to ensure the lowest position of the tire
valve.
Connect the nipple to the tire valve. Push the lever
down and x the nipple.
Check pressure with the manometer.
Connect the compressor to the car lighter socket.
• When the required pressure level is reached, dis-
connect the compressor from the car lighter socket.
Release the lock of the joining nipple and remove it
from the valve.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Defort DCC-251N at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Defort DCC-251N in the language / languages: All languages as an attachment in your email.

The manual is 1,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info