7 Technische gegevens
7.1 Technische gegevens
Keteltype MCR 24 MCR 24/28
MI
MCR 30/35
MI
MCR 34/39
MI
Functie verwarming
Aardgas H (G20)
Nominaal nuttig vermogen 40/30
(min./max.)
kW 6.3 /25 6.3 /25 6.6 /31.3 6.8 /35.5
Nominaal nuttig vermogen 80/60
(min./max.)
kW 5.5 / 23.6 5.5 / 23.6 5.7 / 29.5 5.9 / 33.3
Nominaal ketelvermogen kW 24 24/28 30/35 34/39
Minimaal ketelvermogen kW 5.8 5.8 6.1 6.3
Functie sanitair warm
water
Aardgas H (G20)
Nominaal nuttig vermogen kW - 27.4 34.3 38.2
Nominaal ketelvermogen kW 24 24/28 30/35 34/39
Minimaal ketelvermogen kW 5.8 5.8 6.1 6.3
Gas debiet bij nominaal
vermogen (15 ºC -
1013 mbar)
Aardgas H (G20)
m
3
/h
2.4 2.4 3.5 3.9
Aardgas L (G25)
m
3
/h
2.8 2.8 4.1 4.5
Propaan (G31) kg/h 1.9 1.9 2.7 3.0
Rendement Hi 100% nominaal vermogen bij
gemiddelde temperatuur van het
water in de ketel 70°C
% 98.3 98.3 98.2 98
100% nominaal vermogen bij
retourtemperatuur 30°C
% 104.4 104.4 104.4 104.4
30% nominaal vermogen bij
retourtemperatuur 30°C
% 108.7 108.7 109.7 110.5
Rendement Hs 100% nominaal vermogen bij
gemiddelde temperatuur van het
water in de ketel 70°C
% 88.5 88.5 88.4 88.2
100% nominaal vermogen bij
retourtemperatuur 30°C
% 94 94 94 94
30% nominaal vermogen bij
retourtemperatuur 30°C
% 97.9 97.9 98.8 99.5
Maximale temperatuur (Onderbreking veiligheidsthermostaat) °C 110 110 110 110
Stilstandsverlies (ΔT = 30 ºC) W 30 30 29 28
Verlies via de wanden % 1.1 1.1 0.9 0.5
Waterinhoud liters 1.7 1.8 2 2.2
Leeg gewicht, zonder montageframe, zonder frontmantel kg 29 30.5 32 31.5
Verwarmingscircuit
Nominale doorstroming (ΔT = 20 K)
m
3
/h
1.03 1.03 1.29 1.47
Opvoerhoogte (ΔT = 20 K)
mbar
(1)
> 250 > 250 > 200 > 200
Aanvoertemperatuur °C 75/85 75/85 75 75
maximum druk bar 3 3 3 3
Expansievat liters 8 8 8 -
Voordruk van het expansievat bar 1 1 1 1
Minimale bedrijfsdruk bar 0.8 0.8 0.8 0.8
Sanitair-warmwatercircuit
Ingestelde vertrektemperatuur °C 55 55 55 55
(1) 1 mbar = 100 Pa, 1 daPa = 1 mmCE
(2) Temperatuur ingang koud water: 10 ºC
7. Technische gegevens MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI
29
26/07/2010 - 300015863-001-B
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich Vivadens MCR 30-35 MI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich Vivadens MCR 30-35 MI in the language / languages: Dutch as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of De Dietrich Vivadens MCR 30-35 MI

De Dietrich Vivadens MCR 30-35 MI User Manual - English - 36 pages

De Dietrich Vivadens MCR 30-35 MI Installation Guide - German - 84 pages

De Dietrich Vivadens MCR 30-35 MI User Manual - German - 36 pages

De Dietrich Vivadens MCR 30-35 MI Manual - Dutch - 2 pages

De Dietrich Vivadens MCR 30-35 MI User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info