596386
26
Zoom out
Zoom in
Previous page
1/40
Next page
7 Troubleshooting
7.1 Error messages (Sub-status 9)
To display the current error code, proceed as follows:
1. Press the two
f
keys simultaneously. The symbol
Q
flashes.
2. Confirm using key
S
.
5t
is displayed, alternating with the
current status
3
(for example).
3. Press the [+] key. The display shows
5v
and the current error
value (
30
, for example) alternately.
Code
Description Checking / solution
Su:00 The PSU PCB is incorrectly configured Parameter error on the PSU PCB
4 Contact the professional who takes care of maintenance of the
appliance
Su:01 Maximum flow temperature exceeded The water flow in the installation is insufficient
4 Check the circulation (direction, pump, valves)
Su:02 The increase in flow temperature has
exceeded its maximum limit
The water flow in the installation is insufficient
4 Check the circulation (direction, pump, valves)
4 Check the water pressure
Sensor error
4 Contact the professional who takes care of maintenance of the
appliance
Su:07 Maximum difference between the flow
and return temperature exceeded
The water flow in the installation is insufficient
4 Check the circulation (direction, pump, valves)
4 Check the water pressure
Sensor error
4 Contact the professional who takes care of maintenance of the
appliance
Su:08 The RL inlet on the PCU PCB terminal
block is open
Parameter error
4 Contact the professional who takes care of maintenance of the
appliance
Bad connection
4 Contact the professional who takes care of maintenance of the
appliance
Su:09 Live/neutral inversion Parameter error
4 Contact the professional who takes care of maintenance of the
appliance
M002722-A
7. Troubleshooting EGC 25
25
28/05/2015 - 300026082-001-04
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich TWINEO EGC 25 BE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich TWINEO EGC 25 BE in the language / languages: English as an attachment in your email.

The manual is 1,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of De Dietrich TWINEO EGC 25 BE

De Dietrich TWINEO EGC 25 BE Installation Guide - German - 96 pages

De Dietrich TWINEO EGC 25 BE User Manual - German - 44 pages

De Dietrich TWINEO EGC 25 BE User Manual - Dutch - 40 pages

De Dietrich TWINEO EGC 25 BE User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info