3. Use the
(
and
)
keys to switch from one measurement to
another.
Parameters Description Unit
SE 01
Top DHW temperature sensor °C
SE 02
Middle DHW temperature sensor °C
SE 03
Bottom DHW temperature sensor °C
SE 04
Room sensor °C
SE 05
Evaporator temperature sensor °C
SE 06
Electricity tariff:
4 HP1: Peak hours
4 HC0: Off-peak hours
St Su
Operating status / sub-status of the control system
sequence
SP 1
Back-up setpoint °C
SP 2
Compressor setpoint °C
5.2.2. Counters
n
Displaying the counters
1. Press once the MENU key. The SE nS 1 menu is displayed.
2. Press the
)
key 3 times. The Co un 4 menu is displayed.
3. Press the MODE
B
key to go to the Counters menu. The number
of the counter is shown to the right of the display.
4. Use the
(
and
)
keys to switch from one counter to another (See
table below).
5. To exit this menu, press the MODE
B
key.
6. To go back to the main display, press the MENU button.
Meter
Description Unit
1 Total electric energy input for DHW production kWh
2 Electric energy input by the compressor in the last 24 hours
The counter is reset at 00:00 hours every day
Wh
3 Electric energy input by the electrical back-up in the last 24 hours
The counter is reset at 00:00 hours every day
Wh
C003206-D
1x
2x
3x
.
.
.
1
4
3
4
1
2
MENUMODE
C004186-A
1
4
3
4
1
2
MENUMODE
C003210-C
1
1
4
3
4
1
2
MENUMODE
5. Operating the appliance TWH 200E TWH 300E TWH 300EH
19
16/09/2015 - 7605313-001-06
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich Kaliko TWH 300EH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich Kaliko TWH 300EH in the language / languages: English as an attachment in your email.

The manual is 1,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of De Dietrich Kaliko TWH 300EH

De Dietrich Kaliko TWH 300EH Installation Guide - English - 80 pages

De Dietrich Kaliko TWH 300EH User Manual - German - 40 pages

De Dietrich Kaliko TWH 300EH User Manual - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info