607661
52
Zoom out
Zoom in
Previous page
1/80
Next page
Display Operating
mode
Description
M
Automatic or
Comfort
Comfort programme activated
Domestic hot water production is handled by the heat pump and by electrical back-up if necessary
(+ Hydraulic back-up for EH version).
If domestic hot water production is not satisfied by the compressor after a modifiable time delay
(factory setting: 5 hours - Parameter P23), the back-ups start up.
%
Eco Reduced programme activated.
Domestic hot water production is handled by the heat pump alone.
After the compressor stops, the displayed quantity of domestic hot water available may not be
complete (!).
W
Boost
Forced operating activated
Domestic hot water production is handled simultaneously by the heat pump and the electrical back-
up for a modifiable period (factory setting: 6 hours).
> days
Vacation
Holiday period
Shutting down domestic hot water production.
The domestic hot water temperature is kept at 10°C.
6.6 Reading out measured values
6.6.1. Measurements menu
1. Press once the MENU key. The SE nS 1 menu is displayed.
2. Press the MODE
B
key to go to the Measurements menu. The SE
01 menu is displayed.
3. Use the
(
and
)
keys to switch from one measurement to
another.
Parameters
Description Unit
SE 01
Top DHW temperature sensor °C
SE 02
Middle DHW temperature sensor °C
SE 03
Bottom DHW temperature sensor °C
SE 04
Room sensor °C
SE 05
Evaporator temperature sensor °C
SE 06
Electricity tariff:
4 HP1: Peak hours
4 HC0: Off-peak hours
St Su
Operating status / sub-status of the control system
sequence
SP 1
Back-up setpoint °C
SP 2
Compressor setpoint °C
6.6.2. Counters
n
Displaying the counters
1. Press once the MENU key. The SE nS 1 menu is displayed.
C003206-D
1x
2x
3x
.
.
.
1
4
3
4
1
2
MENUMODE
6. Commissioning
TWH 200E TWH 300E TWH 300EH
50
02/06/2015 - 300026515-001-06
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich Kaliko - TWH 200E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich Kaliko - TWH 200E in the language / languages: English as an attachment in your email.

The manual is 5,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of De Dietrich Kaliko - TWH 200E

De Dietrich Kaliko - TWH 200E User Manual - English - 40 pages

De Dietrich Kaliko - TWH 200E User Manual - German - 40 pages

De Dietrich Kaliko - TWH 200E User Manual - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info