481708
34
Zoom out
Zoom in
Previous page
1/44
Next page
Code Messages Description Checking / solution
B08 BL.RL OPEN
The RL inlet on the PCU PCB
terminal block is open
Parameter error
4 Contact the professional who takes care of
maintenance of the appliance
Bad connection
4 Contact the professional who takes care of
maintenance of the appliance
B09 BL.INV. L/N
4 Contact the professional who takes care of maintenance of the appliance
B10
B11
BL.BL INPUT OPEN
The BL inlet on the PCU PCB
terminal block is open
The contact connected to the BL inlet is open
4 Contact the professional who takes care of
maintenance of the appliance
Parameter error
4 Contact the professional who takes care of
maintenance of the appliance
Bad connection
4 Contact the professional who takes care of
maintenance of the appliance
B13 BL. PCU COM
BL.COM PCU-D4
Communication error with the
SCU PCB
Bad connection
4 Contact the professional who takes care of
maintenance of the appliance
SCU PCB not installed in the boiler
4 Contact the professional who takes care of
maintenance of the appliance
B14 BL.WATER MIS.
The water pressure is lower than
0,8 bar
Not enough water in the circuit
4 Top up the installation with water
B15 BL.GAS PRESS
Gas pressure too low Incorrect setting of the gas pressure switch on the SCU PCB
4 Check that the gas valve is fully opened
4 Contact the professional who takes care of
maintenance of the appliance
B16
BL.BAD SU
The SU PCB is not recognised Wrong SU PCB for this boiler
4 Contact the professional who takes care of
maintenance of the appliance
B17 BL.PCU ERROR
The parameters saved on the
PCU PCB are impaired
Parameter error on the PCU PCB
4 Contact the professional who takes care of
maintenance of the appliance
B18 BL.BAD PSU
The PSU PCB is not recognised Wrong PSU PCB for this boiler
4 Contact the professional who takes care of
maintenance of the appliance
B19 BL.NO CONFIG
The boiler has not been
configured
The PSU PCB has been changed
4 Contact the professional who takes care of
maintenance of the appliance
B21 BL. COM SU
Communication error between
the PCU and SU PCBs
Bad connection
4 Contact the professional who takes care of
maintenance of the appliance
B22 BL.FLAME LOS
No flame during operation No ionization current
4 Check that the gas valve is fully opened
4 Contact the professional who takes care of
maintenance of the appliance
B25
BL.SU ERROR
Internal error on the SU PCB
4 Contact the professional who takes care of
maintenance of the appliance
B26 BL.DHW. S.
The DHW tank sensor is
disconnected or short circuited
4 Contact the professional who takes care of
maintenance of the appliance
6. Troubleshooting MCA 15 - MCA 25 MCA 25/28 MI
33
15/06/12 - 300022161-001-01
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich Innovens MCA 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich Innovens MCA 15 in the language / languages: English as an attachment in your email.

The manual is 1,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of De Dietrich Innovens MCA 15

De Dietrich Innovens MCA 15 Installation Guide - German - 152 pages

De Dietrich Innovens MCA 15 User Manual - German - 48 pages

De Dietrich Innovens MCA 15 Manual - Dutch - 2 pages

De Dietrich Innovens MCA 15 User Manual - Dutch - 48 pages

De Dietrich Innovens MCA 15 User Manual - French - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info