608088
16
Zoom out
Zoom in
Previous page
1/20
Next page
16
UNO/2 200, 300, 400, 500 - UNO/1 200, 300, 400, 500 06/02/12 - 300024525-001-B
6 Checking and maintenance
6.1 Solar installation
We recommend that you take out a preventive maintenance contract
to check the fluid level, antifreeze protection, pressure in the system,
leak test and general operation every year or every two years.
It is imperative to drain the solar circuit before any work is
carried out.
6.2 Tank
6.2.1 Magnesium anodes
The magnesium anode must be checked by a qualified professional
at least every 2 years.
6.2.2 Safety valve or safety unit
Have the condition of the anode checked after the first year. The
magnesium anode must be checked by a qualified professional at
least every 2 years.
6.2.3 Descaling
In hard water regions, it is advisable to ask the fitter to descale the
DHW tank exchanger once a year in order to maintain its level of
performance.
6.2.4 Casing
The casing of the DHW tank can be cleaned with soapy water.
6.2.5 Vent device
If the vent device is not used, the installer must check the seal on the
top vent connection.
6.3 Solar circuit
To check operation of the solar system, consult the display on the
control system. A steady red indicator light in fine weather indicates
a malfunction.
The pressure in the solar circuit can be checked on the solar station's
pressure gauge. If the pressure shown is lower than 0.5 bar, call the
installer.
Never carry out work on the solar circuit yourself. Never
work on the safety valve yourself.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich INISOL - UNO-2 400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich INISOL - UNO-2 400 in the language / languages: English as an attachment in your email.

The manual is 1,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of De Dietrich INISOL - UNO-2 400

De Dietrich INISOL - UNO-2 400 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info