628031
6
Zoom out
Zoom in
Previous page
1/68
Next page
4
796
D
A
740
38
L838
E
K
K
532
==
60
162
195 MP
C
B
10
==
594 ==
200
50
50
120
==
1192
387
165
1017
530
285
137
G
H
H
Raccordement
gaz taraudé Ø R
Sortie corps
condenseur
Ø 2 "
Sortie corps
principal = départ
chauffage Ø 2"
Entrée corps
principal Ø 2"
Entrée corps
condenseur Ø 2"
Sortie
condensats
Ø 42
137
Orifice de chasse Ø
1
1/2
"
(bouchonné)
Ø 203 int.
socle hauteur 80mm mini (à réaliser)
(1)
raccordement
fumées
1.2 Dimensions principales
GT 300 C
GTG 300 C - GTI 300 C
Chaudière type GT... GT... GT... GT... GT... GT...
304 C 305 C 306 C 307 C 308 C 309 C
E 1675 1835 1995 2155 2315 2475
G 977 977 977 997 997 997
H 222 222 222 208 208 208
K 300 300 300 350 350 350
L 838 998 1158 1318 1478 1638
M (versions GTG/GTI) 459 459 459 549 549 549
P 490 650 810 970 1130 1290
ø R
20 mbar 3/4” 3/4” 3/4” 1” 1” 1”
300 mbar 3/4” 3/4” 3/4”
796
D
A
740
38
L838
E
K
KP
532
==
60
162
195
C
B
10
==
594 ==
200
50
50
120
==
1192
165
1017
387
285
137
G
H
H
Sortie corps
condenseur
Ø 2 "
raccordement
fumées
Sortie corps
principal = départ
chauffage Ø 2"
Entrée corps
principal Ø 2"
Entrée corps
condenseur Ø 2"
Sortie
condensats
Ø 42
137
Orifice de chasse Ø 1
1/2
"
(bouchonné)
Ø 203 int.
socle hauteur
80mm mini (à réaliser)
(1)
Ø 135
Ø 155
Ø 175
4 Ø M 8 sur
Ø 170
ép. de la porte
avec isolation: 125 mm
4 pointages
sur Ø 200
4 pointages
sur Ø 220
45°
45°
8219N162-F
8219N163-F
Cote (mm)
ABCD
Tableau
130 105 165 738
Standard
Tableau K
355 190 150 755
+ DIEMATIC-m Delta
(1) Prévoir impérativement un socle hauteur mini. 80 mm pour pouvoir raccorder la station de neutralisation avec une pente et hauteur dynamique suffisantes.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich GTG 305 C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich GTG 305 C in the language / languages: German, French as an attachment in your email.

The manual is 6,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of De Dietrich GTG 305 C

De Dietrich GTG 305 C User Manual - German, French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info