TRIO DT 250 - TRIO DT 350 16/07/2015 - 300028005-001-04
5.4 Measured values and adjustment parameters
The regulator has a safety system that cuts off the tank at
temperatures of over 80°C.
Channel Abbreviation Range Increment Factory setting
Collector temperature
TC [-50.0 ... 250.0] °C - -
Calorifier temperature
TS [-50.0 ... 250.0] °C - -
Amount of heat
kWh [0 ... 9999] kWh - -
Pump regime
PC [0 ... 100] % - -
Self-calibration time
tc [0 ... 5] minutes - -
Return temperature
TR -50...250°C - -
Additional temperature
TM -50...250°C - -
Type of installation
ANL
Installation 1
Installation 2
- Installation 1
Temperature difference enabling the passage of the heating
return via the solar tank
DO [0.5 ... 19.5] K 0.1 6
Temperature difference enabling heating return directly to the
boiler
DF [0.4 ... 19.5] K 0.1 4
Reference temperature difference
DT [10 ... 20] K 0.1 20
Zone changeover temperature (tank)
SZ [20 ... 80] °C 0.1 55
Set temperature of the solar calorifier
SX [20 ... 80] °C 0.1 60
Maximum collector temperature
CX [100 ... 125] °C 0.1 100 °C
Self-calibration phase
tu [1 ... 5] minutes 1 3
Pump minimum speed
PN [20 ... 100] % 1 30
Pump command mode
POMP OnOF / PuLS / PSOL PSOL
Tubular solar collector function
FT [0 ... 1] 1 0
Maximum flow rate
Fx [0 … 20] l/min 0.1
Installation 1: 6.7
Installation 2: 4.2
Manual mode
MM [0 ... 4] 1 4
Software version
VN - - 2.00
Measured values
Adjustment parameter
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich DIETRISOL TRIO DT 250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich DIETRISOL TRIO DT 250 in the language / languages: English as an attachment in your email.

The manual is 1,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info