31/08/05 - 300005627-001-A CITY
Operating instructions
- Check that the boiler is connected to the electricity.
- Open the gas valve (See next page).
G : Switch
Turn the switch to the desired operating mode :
8
.
: Boiler stopped (with antifreeze protection)
"
: Boiler in use : Heating; production of domestic hot water *
(recommended mode)
: Boiler in use : production of domestic hot water Only *
I : Setting button
Adjust the heating water temperature
- Stop to the left : = 40 °C
- Hard point : = 75 °C
- Stop to the right : = 90 °C
K : Setting button *
Adjust the domestic hot water temperature
- Stop to the left : = 40 °C
- Hard point : = 53°C to 55 °C depending on the model
- Stop to the right : = 58°C to 60°C depending on the model
B : Domestic hot water temperature maintenance override
button
For City with Easymatic or Easyradio control unit
Pressing for 1 second in summer or summer/winter mode overrides
loading of the domestic hot water tank or of the primary storage tank
outside the time slot programmed on the control unit up to midnight
(indicator light B2 flash)
Light B1 lit : The burner is ignited to reheat the domestic hot
water tank (or primary storage tank)
Light B2 off : No override or programme running
Light B2 lit : Comfort programme activated
For City without control unit
Light B1 lit : The burner is ignited to reheat the domestic hot water
tank (or primary storage tank)
A power cut does not modify the selected operating mode.
D : Unlock button
If the boiler has locked itself out (warning light C lit), press button D
to re-ignite it. If a 2nd reset turns out to be necessary and remains
unsucessful, consult your fitter.
M : Pressure indicator
Displays the pressure in the heating circuit from 0.5 to 2.5 bar. If the
red warming light (0.5 bar) is lit, top up with water using the filling
system (disconnector, consult your fitter (See next page).
E and F : "Chimney sweep" button and "Fitter" button
These 2 buttons are for use only by the fitter.
Boiler ignition may be provoked by :
- A request for heat from the room thermostat, if being used.
- A request for heat by the boiler thermostat (Setting button I).
- Drawing off dometic hot water or a request for heat by the tank*.
- Temperature maintenance in the primary storage tank (City 2.24/
II).
* only for boilers with tank and City 2.24/II.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich City 3.24-II Chimney at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich City 3.24-II Chimney in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info