607551
47
Zoom out
Zoom in
Previous page
1/52
Next page
1.4 Circulation pump
Note
The benchmark for the most efficient circulators is EEI ≤ 0.20.
1.5
Disposal and Recycling
Warning
Removal and disposal of the boiler must be carried out by a quali
fied installer in accordance with local and national regulations.
Proceed as follows to dismantle the boiler:
1. Cut the electrical power to the boiler.
2. Close the oil shut-off device upstream of the boiler.
3. Disconnect the cables on the electrical components.
4. Close the water mains.
5. Drain the installation.
6. Remove the air vent hose above the siphon.
7. Remove the siphon.
8. Remove the air/flue gas pipes.
9. Disconnect all pipes on the underside of the boiler.
10. Scrap or recycle the boiler.
1.6 Product fiche
Tab.2 Product fiche for boiler space heaters
AFC 18 AFC 24 AFC 30
Seasonal space heating energy efficiency class
A
A
A
Rated heat output
(Prated or Psup)
kW 17 23 29
Seasonal space heating energy efficiency % 90 90 90
Annual energy consumption GJ 54 74 93
Sound power level L
WA
, indoors - for a type B air/flue gas con
nection
dB 60 65 63
Sound power level L
WA
, indoors - for a type C air/flue gas con
nection
dB 58 63 59
See
For specific precautions about assembling, installing and main
taining: See Safety Instructions
1.7
Product data sheet - Temperature controls
Tab.3 Product data sheet for the Temperature controls
DIEMATIC iSystem
Class II
Contribution to space heating energy efficiency % 2
Fig.1 Recycling
MW-3000179-03
Fig.2 Cutting the mains supply
MW-0000149-1
1 Specific information
4 300026440 - ErP01 - 20072015
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich AFC 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich AFC 30 in the language / languages: English as an attachment in your email.

The manual is 1,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of De Dietrich AFC 30

De Dietrich AFC 30 Installation Guide - German - 188 pages

De Dietrich AFC 30 User Manual - German - 52 pages

De Dietrich AFC 30 User Manual - Dutch - 56 pages

De Dietrich AFC 30 User Manual - French - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info