607549
12
Zoom out
Zoom in
Previous page
1/52
Next page
Boiler AFC 18 AFC 24 AFC 30
Minimum
power
Full
power
Minimum
power
Full
power
Minimum
power
Full
power
LHV efficiency 100 % Nominal
output (Pn) at
80/60°C
% 96.3 97.2 96.4 97.1 95.9 97.4
Flue gas
temperature
°C <60 <70 <60 <70 <65 <75
100 % Nominal
output (Pn) at
50/30°C
% 101.5 102.1 101.4 102 101.1 101.6
Flue gas
temperature
°C <40 <45 <40 <45 <45 <50
100 % Nominal
output (Pn) at
40/30°C
% 102.9 103.5 102.6 103.2 102.5 103
Flue gas
temperature
°C <40 <45 <40 <45 <45 <50
Annual efficiency
Hi
at 75/60°C % 101.1 100.9 100.7
at 40/30°C % 105.3 105.1 104.6
Pressure available at the flue gas
nozzle (Pn)
mbar
(1)
0.14 0.22 0.33
Pa 14 22 33
CO
2
content (Minimum output - Start-
up output - Maximum output
% 12 - 13 - 13 12 - 13 - 13 12 - 13 - 13
Nominal water
flow rate at Pn
(50/30 °C)
ΔT = 20K
m
3
/h
0.773 1.032 1.291
Stand-by losses ΔT = 30K W 109 109 128
Percentage of
losses through
the walls
compared with
the stand-by
losses
ΔT = 30K % 61 61 63
Loss of load
hydraulic circuit
(Pn)
ΔT = 20K
mbar
(2)
16.0 29.0 46.0
Electrical power of the boiler only with
no accessories
W 128 272 128 272 128 272
Water content litres 47 47 58
Mass flue gas flow rate (Nominal
output Pn 50/30 °C)
kg per sec 0.0075 0.01 0.0125
Kg/h 27 36 45
Net weight (without packaging) kg 117 117 135
(1) These values are pertinent for flexible flue gas evacuation systems with a diameter of 80 mm (rigid ducts). The length of rigid flue gas
evacuation systems is restricted to 18 metres for technical reasons relating to start-up.
(2) 1 mbar = 10 mmWG = 100 Pa
3. Technical specifications AFC 18 - AFC 24 - AFC 30
11
15/07/2015 - 300026440-05
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich AFC 18 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich AFC 18 in the language / languages: English as an attachment in your email.

The manual is 1,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of De Dietrich AFC 18

De Dietrich AFC 18 Installation Guide - German - 188 pages

De Dietrich AFC 18 User Manual - German - 52 pages

De Dietrich AFC 18 User Manual - Dutch - 56 pages

De Dietrich AFC 18 User Manual - French - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info