535571
24
Zoom out
Zoom in
Previous page
1/36
Next page
DATALOGIC
CONFIGURATION DU LECTEUR PAR DEFAUT
FORMAT DES DONNEES
Code d’identification désactivé (activé pour les terminaux POS), ajustement de
champ désactivé, transmission de la longueur du code désactivée, substitution
de caractère désactivé
ECONOMIE D’ENERGIE
Etat de veille/suspension USB désactivé, entrée en veille = 0.6 sec
PARAMETRES DE LECTURE
Opération manuelle = trigger activé, mode stand = automatique, activation du
trigger = instantané, Flash On = 1 sec, Flash Off = 0.6 sec, une lecture par
cycle, temps de sécurité = 0.5 sec, volume du beeper = fort, tonalité 2, beeper
monotone, durée beeper = court
PARAMETRES DE DECODAGE
« ink spread » activé, contrôle « overflow » activé, contrôle « interdigit » activé,
Puzzle Solver™ activé, sécurité de décodage = une lecture
SELECTION DES CODES
Codes activés
EAN 8/EAN 13 / UPC A/UPC E sans ADD ON
Transmission de la clé de contrôle, pas de conversion
Interleaved 2/5
Vérification et transmission de la clé de contrôle, longueur variable de 4 à
99 caractères
Standard Code 39
Vérification de la clé de contrôle désactivé, longueur variable de 1 à 99
caractères
Code 128
Longueur variable de 1 à 99 caractères
EAN 128, ISBT128, Code 93, Codabar, codes pharmaceutiques, MSI,
Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49,
GS1 DataBar™ (GS1 DataBar™ inclus les symbologies suivantes: RSS-
14, RSS-14 Stacked, RSS Expanded et RSS Limited).
PARAMETRES DE FORMATAGE AVANCE
Concaténation désactivée, pas de format défini
PARAMETRES DE LA RADIO
« Radio protocol timeout » = 2 secondes, « power-off timeout » = 4 heures,
« single store » désactivé, beep de bonne réception radio = normal
20
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic QuickScan I QD2100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic QuickScan I QD2100 in the language / languages: French as an attachment in your email.

The manual is 0,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Datalogic QuickScan I QD2100

Datalogic QuickScan I QD2100 User Manual - English - 28 pages

Datalogic QuickScan I QD2100 User Manual - Spanish - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info