535585
36
Zoom out
Zoom in
Previous page
1/44
Next page
PowerScan™ M8500 Readers
Industrial Handheld Area Imager
Bar Code Reader with
Datalogic’s STAR Cordless System™
Quick Reference Guide
Datalogic ADC, Inc.
959 Terry Street
Eugene, OR 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
©2009-2013 Datalogic, Inc.
An Unpublished Work - All rights reserved. No part of the contents of this docu-
mentation or the procedures described therein may be reproduced or transmitted
in any form or by any means without prior written permission of Datalogic ADC,
Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic ADC”). Owners of Data-
logic products are hereby granted a non-exclusive, revocable license to reproduce
and transmit this documentation for the purchaser's own internal business pur-
poses. Purchaser shall not remove or alter any proprietary notices, including copy-
right notices, contained in this documentation and shall ensure that all notices
appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed ver-
sions by contacting your Datalogic representative. Electronic versions may either
be downloadable from the Datalogic website (www.datalogic.com) or provided on
appropriate media. If you visit our website and would like to make comments or
suggestions about this or other Datalogic publications, please let us know via the
"Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual
that is complete and accurate, however, Datalogic reserves the right to change any
specification at any time without prior notice.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in
many countries, including the U.S.A. and the E.U. All other brand and product
names may be trademarks of their respective owners.
Patents
This product may be covered by one or more of the following patents:
Design Pat. AU 310201; AU 310202; CN 693980; CN735959; HK 0602013.5M001; HK
0602013.5M002; JP 1305693; KR 30-0460940; US D570,843 S; USD588,596 S.
US Pat. 5,992,740; 6,305,606 B1; 6,517,003; 6,808,114 B1; 6,997,385 B2; 7,387,246 B2;
5,367,151; 5,449,893; 5,545,889; 6,098,877; 6,220,514 B1; 6,412,698 B2; 6,607,132 B1;
6,817,529 B2; 6,834,805 B2; 7,948,214 B2.
European Pat. 789,315 B1; 895,175 B1; 1,128,314 B1; 1,128,315 B1; 1,396,811 B1;
1,413,971 B1; 1,816,585 B1; 1,942,442 B1.
Additional patents pending.
Table of Contents
PowerScan™ M8500 Family ............................................................ 1
Description .....................................................................................................1
Using the PowerScan™ PM8500 Family ...............................................2
Indicators ........................................................................................................3
LED Indicators .......................................................................................3
Beeper......................................................................................................3
Good Read Spot ...................................................................................3
Charging the Batteries ...............................................................................4
Setup ................................................................................................................6
PowerScan™ M8500 Configuration .......................................................7
PowerScan™ M8500/BC-80X0 Point-to-Point Setup...............7
PowerScan™ M8500/BC-80X0 Stand Alone Setup...................8
Using Multiple Readers with Same Cradle................................11
PowerScan™ M8500/STAR-MODEM™ Stand Alone Setup ..11
PowerScan™ M8500/STAR-SYSTEM™ Setup.............................12
Default Configuration ..............................................................................15
Operating Test ............................................................................................16
Technical Features ....................................................................................17
Services and Support ...............................................................................22
Regulatory Information ...........................................................................23
Compliance..........................................................................................23
FCC Compliance .................................................................................23
Radio Compliance..............................................................................23
IC (Industry Canada)..........................................................................23
Power Supply ......................................................................................24
Laser Safety ..........................................................................................28
WEEE Compliance..............................................................................32
Datalogic ADC Limited Factory Warranty .................................33
Numeric Table .............................................................................................36
NOTES
Quick Reference Guide 1
PowerScan™ M8500 Family
Description
The PowerScan™ M8500 series readers can be used with either a BC-80X0 cradle
or Stargate™ radio base station to build a Cordless Reading System for the collec-
tion, decoding and transmission of bar coded data. The M8500 series can be used
in the same environment where M8300 series readers are already installed.
This manual includes just the commands required for the startup of the scanner
and setting of the interface. For complete configuration of the scanner, refer to the
PowerScan™ PM8500 Reference Manual or the Datalogic Aladdin configuration
program, both downloadable from the website and available on the included CD
ROM.
The PowerScan™ PM8500 Hand-Held Reader packs a lot of performance into
an attractive, rugged, hand-held device. It operates in commercial and industrial
environments, as well as the front office
.
Omni-
Directional
Operating
To read a symbol or capture an image, you simply aim the reader
and pull the trigger. Since the PowerScan™ PM8500 is a powerful
omni-directional reader, the orientation of the symbol is not
important.
Decoding
Thanks to powerful algorithms, PowerScanPM8500 reliably
decodes all major 1D (linear) bar codes, 2D stacked codes (such as
PDF417), 2D matrix symbols (such as DataMatrix), postal codes (such
as POSTNET, PLANET). The data stream acquired from decoding a
symbol — is rapidly sent to the host. The reader is immediately
available to read another symbol.
Formatting and
Concatenating
The string of a decoded code may be processed according to
either a simple or advanced data formatting and be concatenated
to other codes (up to 4 different codes).
Autoscanning
An autoscan command causes the reader to scan continuously and
to monitor the central zone of its reading area.
Flash Memory
Flash technology allows you to upgrade the PowerScan™ PM8500
reader as new symbologies are supported or as improved
decoding algorithms become available.
USA Driver
License Parsing
The reader can be set up to select and output a subset of data
elements from USA Driver License PDF417 bar codes. This feature
can be enabled using either Datalogic Aladdin™ or the bar codes in
the USA Driver License Parsing Quick Reference Guide (QRG),
available on the Datalogic website.
The Powerscan M8500 is compatible with BC80x0 v3.0.0.00 (available in
the Aladdin Software on the CD included with this product) and later
releases. If a previous firmware version is installed in your BC80x0, please
upgrade to the latest version before installing the M8500.
Using the PowerScan™ PM8500 Family
2PowerScan M8500
Using the PowerScan™ PM8500 Family
The PowerScan™ PM8500 normally functions by capturing and decoding codes.
The PowerScan™ PM8500 reader uses an intelligent aiming system. By pulling
the trigger, the aiming system indicates a field of view, which should be positioned
over the code:
Aiming System
When you pull the trigger, a red beam illuminates the code. If the aiming system
is centered and the entire symbology is within the aiming system, you will get a
good read. The field of view changes size as you move the reader closer or farther
away from the code.
Relative Size and Location of Aiming System Pattern
Successful reading is signaled by an audible tone plus a good-read green LED.
The PowerScan™ PM8500 handheld reader aiming system is designed for
general reading and decoding of 1D and 2D symbols. Some variation in
reading distance will occur due to narrow bar width and other factors.
If reading codes positioned on reflective surfaces, it may be necessary to
tilt the reader with respect to the bar code and/or set the Camera Control
parameters. For configuring the Camera Control parameters refer to the
PowerScan™ PM8500 Product Reference Guide (PRG) available on the
website and the CD.
Linear bar code
2D Matrix symbol
Indicators
Quick Reference Guide 3
Indicators
LED Indicators
The PowerScan™ PM8500 family uses green LED indicators to signal the follow-
ing reader functions:
Beeper
The PowerScan™ PM8500 basic software provides beeper signals for good/wrong
reading and for indicating errors. Its tone, volume and duration can be directly
configured by using the codes given in the PowerScan™ PM8500 Product Refer-
ence Guide (PRG) available on the website.
The application program can also manage the beeper (User Defined Beeper) when
the reader is controlled by a Host PC. It is possible to activate the beeper by send-
ing a command from the Host to the reader via the current communication inter-
face.
Good Read Spot
A green good read spot will be projected in the field of view when the reading is
successful.
STATUS BEHAVIOR
Power ON At power-on, the LEDs blink briefly, then light up for 2
seconds to signal the power supply is present.
Normal Function The LED lights up after a good decoding and will
switch off only at the next trigger press.
Charging the Batteries
4PowerScan M8500
Charging the Batteries
Once the BC-80X0/C-8000 is powered, you can charge the reader's batteries.
Place the PowerScan™ M8500 into the BC-80X0 cradle or the C-8000 battery
charger. The "Reader" LED on the cradle/battery charger turns red.
The battery is completely charged when the "Reader" LED on the cradle/battery
charger turns green.
To change the battery, push the Release Button as indicated by Arrow 1 and
extract the battery pack from the reader handle. Then, insert the new battery pack
into the reader handle until a ‘clickis heard and the Release Button moves back to
its neutral position.
1
2
Charging the Batteries
Quick Reference Guide 5
As with other types of batteries, Lithium-Ion (LI) batteries will lose capacity over time. Capacity deteri-
oration is noticeable after one year of service whether the battery is in use or not. It is difficult to pre-
cisely predict the finite life of a LI battery, but cell manufacturers rate them at 500 charge cycles. In
other words, the batteries should be expected to take 500 full discharge/charge cycles before needing
replacement. This number is higher if partial discharging / recharging is adhered to rather than full /
deep discharging,
The typical manufacturer advertised useful life of LI batteries is one to three years, depending on
usage and number of charges, etc., after which they should be removed from service, especially in mis-
sion critical applications. Do not continue to use a battery that is showing excessive loss of capacity, it
should be properly recycled / disposed of and replaced. For most applications, batteries should be
replaced after one year of service to maintain customer satisfaction and minimize safety concerns.
Collect and recycle waste batteries separately from the device in compliance with European Directive
2006/66/EC, 2011/65/EU, 2012/19/EU. and subsequent modifications, US and China regulatory and oth-
ers laws and regulations about the environment.
WARNING
Do not discharge the battery using any device except for the scanner.
When the battery is used in devices other than the designated product, it
may damage the battery or reduce its life expectancy. If the device causes
an abnormal current to flow, it may cause the battery to become hot,
explode or ignite and cause serious injury.
Lithium-ion battery packs may get hot, explode or ignite and cause seri-
ous injury if exposed to abusive conditions. Be sure to follow the safety
warnings listed below:
• Do not place the battery pack in fire or heat.
• Do not connect the positive terminal and negative terminal of the battery pack
to each other with any metal object (such as wire).
• Do not carry or store the battery pack together with metal objects.
• Do not pierce the battery pack with nails, strike it with a hammer, step on it or
otherwise subject it to strong impacts or shocks.
• Do not solder directly onto the battery pack.
• Do not expose the battery pack to liquids, or allow the battery to get wet.
• Do not apply voltages to the battery pack contacts.
In the event the battery pack leaks and the fluid gets into your eye, do not
rub the eye. Rinse well with water and immediately seek medical care. If
left untreated, the battery fluid could cause damage to the eye.
CAUTION
Always charge the battery at 32° – 104°F (0° - 40°C) temperature range.
Use only the authorized power supplies, battery pack, chargers, and
docks supplied by your Datalogic reseller. The use of any other power
supplies can damage the device and void your warranty.
Do not disassemble or modify the battery. The battery contains safety
and protection devices, which, if damaged, may cause the battery to
generate heat, explode or ignite.
Do not place the battery in or near fire, on stoves or other high tempera-
ture locations.
Do not place the battery in direct sunlight, or use or store the battery
inside cars in hot weather. Doing so may cause the battery to generate
heat, explode or ignite. Using the battery in this manner may also result
in a loss of performance and a shortened life expectancy.
Do not place the battery in microwave ovens, high-pressure containers
or on induction cookware.
Immediately discontinue use of the battery if, while using, charging or
storing the battery, the battery emits an unusual smell, feels hot,
changes color or shape, or appears abnormal in any other way.
Do not replace the battery pack when the device is turned on.
Do not remove or damage the battery pack’s label.
Do not use the battery pack if it is damaged in any part.
Battery pack usage by children should be supervised.
Setup
6PowerScan M8500
Setup
PowerScan™ M8500/BC-80X0 Point-to Point Configuration
1. Connect a BC-80X0 cradle to the Host. For installation and connection
information see the BC-80X0 Quick Reference Manual.
2. Charge the PowerScan™ M8500 battery using an BC-80X0 or the
C-8000 char
ger as described in this Quick Reference manual. A full
charge takes 4 hours if using an external power supply; while it takes up
to 10 hours if supplying power through the USB port.
3. Configure the reader as described in this Quick Reference -
PowerScan™ M8500/BC-80X0 Point-to-Point Setup.
4. Configure the BC-80X0 cradle. See BC-80X0 Configuration in the BC-
80X0 Quick Reference.
or
PowerScan™ M8500/BC-80X0 Stand Alone Configuration
1. Connect an BC-80X0 cradle to the Host. For installation and connection
information see the BC-80X0 Quick Reference Manual.
2. Charge the PowerScan™ M8500 battery using an BC-80X0 or the
C-8000 char
ger as described in this Quick Reference manual. A full
charge takes 4 hours if using an external power supply; while it takes up
to 10 hours if supplying power through the USB port.
3. Configure the reader as described in this Quick Reference -
PowerScan™ M8500/BC-80X0 Stand Alone Setup.
4. Configure the BC-80X0 cradle. See BC-80X0 Configuration in the
BC-80X0 Quick Reference.
or
PowerScan™ M8500/STAR-System™ Configuration
1. Charge the PowerScan™ M8500 battery using an BC-8000 or the
C-8000 charger as described in this Quick Reference manual. A full
charge takes 4 hours if using an external power supply; while it takes up
to 10 hours if supplying power through the USB port.
2. Configure the reader as described in this Quick Reference -
P
owerScan™ M8500/STAR-System™ Setup.
PowerScan™ M8500 Configuration
Quick Reference Guide 7
PowerScan™ M8500 Configuration
PowerScan
M8500/BC-80X0 Point-to-Point Setup
A rapid configuration procedure has been devised for point-to-point applications
where a single reader is associated exclusively with its own BC-80X0 base station
and where it is not necessary to set the Date and Time parameters.
A special pre-printed bind-address label provided in the BC-80X0 base station
package can be used to bind the PowerScan™ M8500 reader to the base station
with the address coded on the label. The address is also written numerically on the
label to be easily recognized. Valid addresses are in the range from 0000 to 1999.
Make sure that all cradles used in the same area have different addresses.
To rapidly configure your point-to-point application:
1. Apply the bind-address label onto the
BC-80X0 base station as indicated
in the BC-80X0 Quick Reference Manual.
2. When the BC-80X0 cradle is connected
and powered, read the Bind-
Address label to pair the PowerScan™ M8500 to the BC-80X0 cradle.
The green LED on the PowerScan™ M8500 will blink: the reader is ready
to be positioned onto the cradle.
3. Firmly position the reader onto the cradle within 10 seconds, a beep will
be emitted, signaling that the BC-80X0 cradle has been paired to the
PowerScan™ M8500, and the green LED on the reader will go off.
4. Configure the BC-80X0 cradle, refer to the “BC-80X0 Quick Reference”.
END of procedure. YOUR READER IS NOW READY TO READ CODES.
If it ever becomes necessary to
change
the reader, just read the
bind-address label applied to the
cradle and position the new reader
onto the cradle.
Do not use multiple readers with
this configuration method.
Green LED
PowerScan™ M8500 Configuration
8PowerScan M8500
PowerScan™ M8500/BC-80X0 Stand Alone Setup
When the BC-80X0 cradle is connected and powered, configure the PowerScan™
M8500 by reading the following codes in the given sequence and follow the instruc-
tions.
For the numeric code selection of steps 3, 4, and 5 use the table at the end
of this Quick Reference
1. Restore PowerScan™ M8500 Default
2. Enter Configuration
3. Set Date
+
six digits for Day, Month and Year (DDMMYY).
4. Set Time
PowerScan™ M8500 Configuration
Quick Reference Guide 9
+
four digits for Hours and Minutes (HHMM).
5. Set Radio Address
+
four digits for the PowerScan™ M8500 Address
(from 0000 to 1999).
All readers used in the same area must have different addresses.
6. Exit and Save Configuration
7. Read the Bind code to pair the PowerScan™ M8500 to the BC-80X0 cradle.
The reader is dedicated to the cradle. Any previously bound reader will be
excluded.
To connect several readers to the same cradle see the following section "Using
Multiple Readers with Same Cradle".
Bind
The green LED on the PowerScan™ M8500 will blink: the reader is ready to be
positioned onto the cradle.
8. Firmly position the reader onto the cradle within 10 seconds, a beep will be
emitted, signaling that the BC-80X0 cradle has been paired to the
PowerScan™ M8500, and the green LED on the reader will go off.
PowerScan™ M8500 Configuration
10 PowerScan™ M8500
END of procedure. YOUR READER IS NOW READY TO READ CODES.
9. Configure the BC-80X0 cradle, refer to the “BC-80X0 Quick Reference”.
Green LED
PowerScan™ M8500 Configuration
Quick Reference Guide 11
Using Multiple Readers with Same Cradle
If you want to use several readers associated with the same cradle, you must first
Bind the cradle with one of the readers (see previously described configuration
procedure).
Successive readers can be associated with the same cradle by following the con-
figuration procedure substituting the Bind command with Join.
END of procedure.
PowerScan
M8500/STAR-MODEM™ Stand Alone Setup
To configure a PowerScan™ M8500 reader to communicate with STAR-
Modem™ in Stand Alone Mode, follow the "PowerScan™ M8500/BC-80X0
Stand Alone Setup" procedure substituting steps 5 and 6 with those below:
END of procedure. YOUR READER IS NOW READY TO READ CODES.
7. Join
The g
reen LED on the PowerScan™ M8500 will blink: the reader is ready to be
positioned onto the cradle. Complete step 8.
CAUTION
All readers associated with the same cradle must have different
addresses.
6. STAR-Modem™ Address
Read the code above and the four-digit address of the STAR-Modem™.
7. Exit and Save Configuration
PowerScan™ M8500 Configuration
12 PowerScan™ M8500
PowerScan
M8500/STAR-SYSTEM™ Setup
The following procedure allows configuring a PowerScan™ M8500 reader to
communicate with various STAR-System™ devices such as Stargate™ RF base
stations:
1. Restore PowerScan™ M8500 Default
2. Enter Configuration
3. Set Date
+
six digits for Day, Month and Year (DDMMYY).
4. Set Time
+
four digits for Hours and Minutes (HHMM).
PowerScan™ M8500 Configuration
Quick Reference Guide 13
5. Set the connection according to the length of the codes to be read:
Code Length 240 Characters
Code Length 240 Characters
(not for systems with BC-80X0 as Master)
6. Set Radio Address
+
four digits from the Numeric Table for the PowerScan™ M8500 Address
(from 0000 to 1999).
All readers used in the same area must have different addresses.
7. Set First STAR-System™ Address
+
four digits from the Numeric Table in the range 0000 to 1999
PowerScan™ M8500 Configuration
14 PowerScan™ M8500
END of procedure. YOUR READER IS NOW READY TO READ CODES.
8. Set Last STAR-System™ Address
+
four digits from the Numeric Table in the range 0000 to 1999
Whenever the system is composed of a single base station, the first
and last base station addresses (steps 7 and 8) must have the same
value.
9. Exit and Save Configuration
Default Configuration
Quick Reference Guide 15
Default Configuration
DATA FORMAT – Symbology Dependent Parameters
symbology specific format = select all, no headers, no terminators, symbology character
substitution disabled, symbology character deletion disabled
DATA FORMAT – Concatenation
Concatenation disabled, 2 EAN/UPC codes concatenated, Set First Concatenated Code
Length 000 = any length, Set Second Concatenated Code Length 000 = any length, Set
Third Concatenated Code Length 000 = any length, Set Fourth Concatenated Code Length
000 = any length, Concatenation with Intercode Delay disabled, Concatenation Timeout 10
seconds, Concatenation Failure Transmission = Tx codes causing failure, Transmission after
Timeout = No code transmission, Concatenation Result Code ID = No code Identifier
ADVANCED FORMATTING PARAMETERS
format disabled
CAMERA CONTROL
exposure mode = automatic, based on entire image
CODE SELECTION
issue identical codes = enable
enabled codes
Standard Code 39: no check digit control, variable code length;
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
: UPCE expansion disabled
Code 128
: variable code length
PDF417
Datamatrix: rectangular, normal and inverted, variable code length
QR
disabled codes
Code 32, Interleaved 2/5, Codabar, Code 93, EAN 128, GS1 DataBar™, Micro PDF417, Postal
Codes, Maxicode, Composite Codes
,
Aztec, microQR, IMB.
READING PARAMETERS
trigger type normal, trigger level mode, flash on = 2 sec, flash off = 2 sec, beeper tone =
tone 1, beeper volume = high, beeper duration = 50 ms, user defined beeper = tone 1, user
defined beeper volume = high, user defined beeper duration = 100 ms, code per scan = one
code per scan, read per cycle = one read per cycle, scan timeout = 5 sec, central code
transmission = disabled, order by code length = disabled, order by code symbology =
disabled, autoscan mode = disabled, autoscan aiming system = enabled, autoscan
hardware trigger = enabled, autoscan illumination system = disabled, stand autoscan mode
= normal, aiming system delay = disabled, good read spot = short, safety time = 500 ms
RADIO PARAMETERS
radio protocol timeout = 2 seconds, power-off timeout = 4 hours, transmission mode =
one-way, beeper control for radio response = normal, single store = disabled, batch mode =
disabled, find me = enabled, radio RX timeout = disabled
Operating Test
16 PowerScan™ M8500
Operating Test
EAN-13 Code 39 (Standard)
Code 128
PDF417
QR
Data Matrix (Normal)
1 234567 000992
test
Technical Features
Quick Reference Guide 17
Technical Features
PowerScan™ M8500 Family Common Features
Electrical Features
Battery Type 2150 Li-Ion battery pack
Time of recharge max. 4 hours with external power supply
max. 10 hours with Host power
Operating autonomy
(continuous reading)
30,000 reads (typical)
Display
(Only available with some
models)
LCD 4 lines x 16 chars
Programmable font and backlight
Indicators Good Read LED
green
Good Read Spot
green
Beeper
Radio Features European Models USA Models
Radio Frequency 433.92 MHz 910 MHz
Bit rate 19200 baud 36800 baud
Range (in open air) exceed 50 m exceed 30 m
System Configuration BC-80X0
STARGATE™
Max. number of devices per
base station
32
Max. number of devices in
the same reading area
2000
Environmental Features
Operating Temperature -10° to +50° C (+14° to +122° F)
Storage Temperature -20° to +70° C (-4° to +158° F)
Humidity 0 to 95% NC
Drop Resistance 2 m / 6.6 ft (over 50 drops to concrete)
IP Sealing IP65 (IP64 for models with display)
Mechanical Features
Weight (with batteries) about 360 g (12.70 oz)
Dimensions 212 x 109 x 71 mm (8.34 x 4.29 x 2.79 in)
Material Polycarbonate molded with rubber
Decoding Capability
1D Interleaved 2 of 5, Code 39, Code 32, Code 128, EAN 128,
Code93, UPC/EAN/JAN, Codabar, GS1 DataBar™
2D Aztec, PDF417, Micro PDF417, Macro PDF417, Maxicode,
DataMatrix (ECC200), QR, Composite Codes
Postal Codes PLANET, Japan Post, Australia Post, KIX Code, Royal Mail Code
(RM4SCC)
Technical Features
18 PowerScan™ M8500
PowerScan™ M8500 Family Common Features (continued)
Optical Features
Sensor 1280 x 1024 pixel element, 2D CMOS Array
Illuminator LED array
Wavelength In the range 630 ~ 670 nm
LED Safety Class Class 1 to EN 60825-1
Aiming System Visible Laser Diode
Wavelength 650 nm
Laser Safety Class Class 2 - EN 60825-1; Class II CDRH
Ambient light 0 - 100000 lux
Technical Features
Quick Reference Guide 19
PowerScan™ M8500™
* Reading distances are measured from the nose of the reader.
NOTE: Typical performance at 20ºC / 68ºF on high quality bar codes.
Optical Features
Focus distance 140 mm
Field of view 28°(H )x 23°(V)
Horizontal field of view at
distance (
d
) in mm
0.52
d
+ 15
Vertical field of view at distance
(
d
) in mm
0.42
d
+ 12
Max Resolution
Linear codes - mm
(mils)
PDF417 - mm
(mils)
Datamatrix – mm
(mils)
0.10 (4) 0.10 (4) 0.17 (6.6)
Depth of field*
1D
(linear):
X-dimension
mm (mils)
DOF
cm (in)
Code39 0.13 (5) 7.5 to 15.5
(2.95 to 6.10)
0.5 (20) 5.5 to 36.5
(2.17 to 14.37)
EAN13 0.33 (13) 5.0 to 27
(1.97 to 10.63)
2D: X-dimension
mm (mils)
DOF
cm (in)
PDF417 0.13 (5) 8.0 to 18.5
(3.15 to 7.28)
0.25 (10) 4.0 to 25.5
(1.57 to 10.04)
QR 0.19 (7.5) 8.0 to 16.5
(3.15 to 6.5)
0.25 (10) 7.0 to 19.5
(2.76 to 7.68)
DataMatrix 0.19 (7.5) 8.0 to 16.5
(3.15 to 6.5)
0.25 (10) 7.0 to 19.5
(2.76 to 7.68)
Skew ±40°
Pitch ±35°
Rotation 360°
Print Contrast (Min.) 15%
Technical Features
20 PowerScan™ M8500
PowerScan™ M8500™ HD
Reading distances are measured from the nose of the reader.
NOTE: Typical performance at 20ºC / 68ºF on high quality bar codes.
Optical Features
Focus distance 65 mm
Field of view 27° (H) x 22° (V)
Horizontal field of view at
distance (
d
) in mm
0.50
d
+ 13
Vertical field of view at distance
(
d
) in mm
0.40
d
+ 10
Max Resolution Linear codes - mm
(mils)
PDF 417 –
mm (mils)
Datamatrix –
mm (mils)
0.05 (2 mils) 0.08 (3 mils) 0.10 (4 mils)
Depth of field*
1D
(linear):
X-dimension
mm (mils)
DOF
cm (in)
Code39 0.08 (3) 4.5 to 8.0 (1.77 to 3.15)
0.13 (5) 3.5 to 9.5 (1.38 to 3.74)
0.51 (20) 6.0 to 18.5 (2.36 to 7.28)
EAN13 0.33 (13) 5.0 to 14 (1.97 to 5.51)
2D
:
X-dimension
mm (mils)
DOF
cm (in)
PDF417 0.08 (3) 5.0 to 8.5
(1.97 to 3.35)
0.13 (5) 4.5 to 9.5
(1.77 to 3.74)
0.25 (10) 3.0 to 13.0
(1.18 to 5.12)
QR 0.10 (4) 5.5 to 7.5
(2.17 to 2.95)
0.19 (7.5) 5.0 to 8.0
(1.97 to 3.15)
0.25 (10) 4.5 to 9.5
(1.77 to 3.74)
DataMatrix 0.10 (4) 5.5 to 7.5
(2.17 to 2.95)
0.19 (7.5) 5.0 to 8.0
(1.97 to 3.15)
0.25 (10) 4.5 to 9.5
(1.77 to 3.74)
Skew ±40°
Pitch ±35°
Rotation 360°
Print Contrast (Min.) 23%
Technical Features
Quick Reference Guide 21
PowerScan™ M8500™ WA
Reading distances are measured from the nose of the reader.
NOTE: Typical performance at 20ºC / 68ºF on high quality bar codes.
Optical Features
Focus distance 110 mm
Field of view 57° x 46°
Horizontal field of view at
distance (
d
) in mm
1.09
d
+ 38
Vertical field of view at distance
(
d
) in mm
0.85
d
+ 30
Max Resolution Linear codes - mm
(mils)
PDF 417 – mm
(mils)
Datamatrix – mm
(mils)
0.13 (5 mils) 0.13 (5 mils) 0.19 (7.5 mils)
Depth of field*
1D
(linear):
X-dimension
mm (mils)
DOF
cm (in)
Code39 0.13 (5) 2.5 to 10.0
(0.98 to 3.94)
0.51 (20) 1.5 to 32
(0.59 to 12.60)
EAN 13 0.33 (13) 1.5 to 26.0
(0.59 to 10.24)
2D
:
X-dimension
mm (mils)
DOF
cm (in)
PDF417 0.13 (5) 3.0 to 10.5
(1.18 to 4.13)
0.25 (10) 1.5 to 21.5
(0.59 to 8.46)
QR 0.19 (7.5) 5.5 to 8.5
(2.17 to 3.35)
0.25 (10) 3.0 to 12.5
(1.18 to 4.92)
DataMatrix 0.19 (7.5) 5.5 to 8.5
(2.17 to 3.35)
0.25 (10) 3.0 to 12.5
(1.18 to 4.92)
Skew ±40°
Pitch ±35°
Rotation 360°
Print Contrast (Min.) 15%
Services and Support
22 PowerScan™ M8500
Services and Support
Datalogic provides several services as well as technical support through its website.
Log on to www.scanning.datalogic.com and click on the links indicated for
further information including:
Products
Search through the links to arrive at your product page where you can download
specific Manuals and Software & Utilities including:
Datalogic Aladdin™, a multi-platform utility program that allows device
configuration using a PC. It provides RS-232 interface configuration as
well as configuration bar code printing.
Service & Support
Technical Support - Product documentation and programming guides
and Technical Support Department in the world
Service Programs - Warranty Extensions and Maintenance Agreements
Repair Services - Flat Rate Repairs and Return Material Authorization
(RMA) Repairs.
Downloads – Manuals & Documentation, Data Sheets, Product Cata-
logues, etc.
Contact Us
Information Request Form and Sales & Service Network
Regulatory Information
Quick Reference Guide 23
Regulatory Information
Compliance
This device must be opened by qualified personnel only.
The batteries must be removed before opening the device.
FCC Compliance
Modifications or changes to this equipment without the express written approval
of Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference which
may cause undesired operation.
FCC ID U4F0015.
Radio Compliance
Contact the competent authority responsible for the management of radio frequency
devices of your country to verify any possible restrictions or licenses required.
Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm for
fu
rther information.
IC (Industry Canada)
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Aiming System Laser Beam Output Window
Laser warning and classification label
Regulatory Information
24 PowerScan™ M8500
Power Supply
Argentina Statement
Cofetel Mexico Update
Atenon
Características de la
fuente de alimentación
eléctrica.
Entrada:
100 - 240 Vca
400mA min 50/60 Hz
Salida:
12VDC, 1500mA máx
(-)Negativo al centro
Utilice en su red solo fuentes certificadas en Argentina.
El uso de fuentes de alimentación no compatibles puede resultar en
riesgo de incendio o de choque eléctrico para el usuario.
Este Producto es usable en Mexico.
Certificado Nr. RCPDAST08-0269 (COFETEL).
La operación de este equipo está sujeta a las siguientes dos
condiciones: (1) es posible que este equipo o dispositivo no
cause interferencia perjudicial y (2) este equipo o dispositivo
debe aceptar cualquier interferencia, incluyendo la que
pueda causar su operación no deseada.
Regulatory Information
Quick Reference Guide 25
Anatel (Brazil conformity)
0730-10-4727
(01)07898916345031
Modelo PowerScan M8500
BC8060 and BC8030 (carregadores)
“Este equipamento opera em caráter secundário, isto é,
não tem direito a proteção contra interferência prejudicial,
mesmo de estações do mesmo tipo, e não pode causar
interferência a sistemas operando em caráter primário.”
Regulatory Information
26 PowerScan™ M8500
China RoHS Table of Restricted Elements (Scanner)
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr(VI))
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
᦭Ქ᦭ኂ‛ᚗర⚛
PART
ㇱઙฬ⒓
౐ચ ᄽ侶૖ ᄽԲ૖ㅘ
Printed Circuit Board Assembly
⬉䏃ᵓ㒘ӊ
X O O O O O
Assy, Optics Block
ܝᄺ㒘ӊ
X O O O O O
Assy, Module
ܝᄺ㒘ӊ
X O O O O O
Oઍ⴫ᱝㇱઙ⊛ᚲ᦭ဋ凝ޗறխࢬܶऱ具Ẋڶ੅ڶ୭ढ凝݁܅Պխ䦀Գا٥ࡉ㧺ॾஒ䣈䢓ຝ咒ؒ⊛
ޝ䶣՗ॾஒ䣈঴խڶ੅ڶ୭ढ凝ऱૻၦ૞ޣρ(SJ/T 11363-2006) 億ࡳऱૻၦޕ
X:ઍ⴫ᱝㇱઙᚲ↪⊛ဋ凝ޗறխ, ⥋ዋ᦭৻᧚ᢱ౔ᚲ฽⊛
᦭Ქ᦭ኂ‛凝೏Պխ䦀Գا٥ࡉ㧺ॾஒ䣈䢓ຝ咒ؒ
ޝ䶣՗ॾஒ䣈঴խڶ੅ڶ୭ढ凝ऱૻၦ૞ޣρ(SJ/T 11363-2006) 億ࡳऱૻ
Regulatory Information
Quick Reference Guide 27
China RoHS Table of Restricted Elements (Base)
ㇱઙฬ⒓
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr(VI))
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
᦭Ქ᦭ኂ‛ᚗర⚛
PART
౐ચ ᄽ侶૖ ᄽԲ૖ㅘ
Printed Circuit Board Assembly
⬉䏃ᵓ㒘ӊ
X O O O O O
Assy, Module
ܝᄺ㒘ӊ
X O O O O O
O
ઍ⴫ᱝㇱઙ⊛ᚲ᦭ဋ凝ޗறխࢬܶऱ具Ẋڶ੅ڶ୭ढ凝݁܅Պխ䦀Գا٥ࡉ㧺ॾஒ䣈䢓ຝ咒ؒ⊛
ޝ䶣՗ॾஒ䣈঴խڶ੅ڶ୭ढ凝ऱૻၦ૞ޣρ(SJ/T 11363-2006) 億ࡳऱૻၦޕ
X:
ઍ⴫ᱝㇱઙᚲ↪⊛ဋ凝ޗறխ, ⥋ዋ᦭৻᧚ᢱ౔ᚲ฽⊛᦭Ქ᦭ኂ‛凝೏Պխ䦀Գا٥ࡉ㧺ॾஒ䣈䢓ຝ咒ؒ⊛
ޝ䶣՗ॾஒ䣈঴խڶ੅ڶ୭ढ凝ऱૻၦ૞ޣρ(SJ/T 11363-2006) 億ࡳऱૻ
Regulatory Information
28 PowerScan™ M8500
Laser Safety
The PowerScan™ PM8500 handheld reader is a Class 1 LED product regarding
its Illuminator and a Class 2 laser product regarding its Aiming System.
LED Illuminator
The use of an illuminator in the PowerScan™ PM8500 handheld reader is a Class
1 LED product:
ILLUMINATORE LED CLASSE 1
AUSLEUCHTER LED KLASSE 1
ILLUMINATEUR A LED DE CLASSE 1
ILUMINADOR LED DE CLASE 1
Aiming System
The PowerScan™ PM8500 aiming system meets the Class 2 requirements for
laser safety.
IDFE
LA LUCE LASER È VIS-
IBILE ALL'OCCHIO
UMANO E VIENE
EMESSA DALLA FIN-
ESTRA INDICATA
NELLA FIGURA.
DIE LASER-STRAH-
LUNG IST FÜR DAS
MENSCHLICHE AUGE
SICHTBAR UND WIRD
AM STRAHLAUS
TRITTSFENSTER AUS-
GESENDET (SIEHE
BILD)
LE RAYON LASER
EST VISIBLE À L'OEIL
NU ET IL EST ÉMIS
PAR LA FENÊTRE
DÉSIGNÉE SUR
L' IL LU S TR AT IO N
DANS LA FIGURE
A LUZ LÁSER ES
VISIBLE AL OJO
HUMANO Y ES
EMITIDA POR LA
VENTANA INDI-
CADA EN LA FIG-
URA.
LUCE LASER NON
FISSARE IL FASCIO
APPARECCHIO LASER
DI CLASSE 2 MAS-
SIMA POTENZA
D'USCITA:
LUNGHEZZA
D'ONDA EMESSA:
CONFORME A EN
60825-1 (2001)
LASERSTRAHLUNG
NICHT IN DEN
STRAHL BLICKEN
PRODUKT DER
LASERKLASSE 2
MAXIMALE AUS-
GANGSLEISTUNG:
WELLENLÄGE:
ENTSPR. EN 60825-1
(2001)
RAYON LASER
EVITER DE
REGARDER LE
RAYON APPAREIL
LASER DE CLASSE 2
PUISSANCE DE
SORTIE:
LONGUEUR
D'ONDE EMISE:
CONFORME A EN
60825-1 (2001)
RAYO LÁSER NO
MIRAR FIJO EL
RAYO APARATO
LÁSER DE CLASE
2 MÁXIMA
POTENCIA DE
SALIDA:
LONGITUD DE
ONDA EMITIDA:
CONFORME A EN
60825-1 (2001)
Regulatory Information
Quick Reference Guide 29
ENGLISH
The following information is provided to comply with the rules imposed by inter-
national authorities and refers to the correct use of your terminal.
STANDARD LASER SAFETY REGULATIONS
This product conforms to the applicable requirements of both CDRH 21 CFR
1040 and EN 60825-1 at the date of manufacture.
For installation, use and maintenance, it is not necessary to open the device.
The product utilizes a low-power laser diode. Although staring directly at the laser
beam momentarily causes no known biological damage, avoid staring at the beam
as one would with any very strong light source, such as the sun. Avoid that the
laser beam hits the eye of an observer, even through reflective surfaces such as mir-
rors, etc.
ITALIANO
Le seguenti informazioni vengono fornite dietro direttive delle autorità internazi-
onali e si riferiscono all’uso corretto del terminale.
NORMATIVE STANDARD PER LA SICUREZZA LASER
Questo prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla
data di produzione: CDRH 21 CFR 1040 e EN 60825-1.
Non si rende mai necessario aprire l’appa-recchio per motivi di installazione, uti-
lizzo o manutenzione.
Il prodotto utilizza un diodo laser a bassa potenza. Sebbene non siano noti danni
riportati dall’occhio umano in seguito ad una esposizione di breve durata, evitare
di fissare il raggio laser così come si eviterebbe qualsiasi altra sorgente di luminos-
ità intensa, ad esempio il sole. Evitare inoltre di dirigere il raggio laser negli occhi
di un osservatore, anche attraverso superfici riflettenti come gli specchi.
DEUTSCH
Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die
von internationalen Behörden auferlegt wurden, und sie beziehen sich auf den
korrekten Gebrauch vom Terminal.
WARNING
Use of controls or adjustments or performance of procedures
other than those specified herein may result in exposure to haz-
ardous visible laser light.
ATTENZIONE
L'utilizzo di procedure o regolazioni differenti da quelle
descritte nella documentazione può provocare un'esposizione
pericolosa a luce laser visibile.
Regulatory Information
30 PowerScan™ M8500
NORM FÜR DIE LASERSICHERHEIT
Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1 und
CDRH 21 CFR 1040 Normen für die Lasersicherheit.
Es ist nicht notwendig, das Gerät wegen Betrieb oder Installations-, und War-
tungs-Arbeiten zu öffnen.
Der Produkt benutzt eine Laserdiode. Obwohl zur Zeit keine Augenschäden von
kurzen Einstrahlungen bekannt sind, sollten Sie es vermeiden für längere Zeit in
den Laserstrahl zu schauen, genauso wenig wie in starke Lichtquellen (z.B. die
Sonne). Vermeiden Sie es, den Laserstrahl weder gegen die Augen eines Beobach-
ters, noch gegen reflektierende Oberflächen zu richten.
FRANÇAIS
Les informations suivantes sont fournies selon les règles fixées par les autorités
internationales et se réfèrent à une correcte utilisation du terminal.
NORMES DE SECURITE LASER
Ce produit est conforme aux normes de sécurité laser en vigueur à sa date de fabri-
cation: CDRH 21 CFR 1040 et EN 60825-1.
Il n’est pas nécessaire d’ouvrir l’appareil pour l’installation, l’utilisation ou l’entre-
tien.
Le produit utilise une diode laser. Aucun dommage aux yeux humains n’a été con-
staté à la suite d’une exposition au rayon laser. Eviter de regarder fixement le
rayon, comme toute autre source lumineuse intense telle que le soleil. Eviter aussi
de diriger le rayon vers les yeux d’un observateur, même à travers des surfaces
réfléchissantes (miroirs, par exemple).
ESPAÑOL
Las informaciones siguientes son presentadas en conformidad con las disposi-
ciones de las autoridades internacionales y se refieren al uso correcto del terminal.
NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER
Este aparato resulta conforme a las normativas vigentes de seguridad láser a la
fecha de producción: CDRH 21 CFR 1040 y EN 60825-1.
ACHTUNG
Jegliche Änderungen am Gerät sowie Vorgehensweisen, die
nicht in dieser Betriebsanleitung beschreiben werden, können
ein gefährliches Laserlicht verursachen.
ATTENTION
L'utilisation de procédures ou réglages différents de ceux don-
nés ici peut entraîner une dangereuse exposition à lumière
laser visible.
Regulatory Information
Quick Reference Guide 31
No es necesario abrir el aparato para la instalación, la utilización o la
manutención.
El aparato utiliza un diodo láser a baja potencia. No son notorios daños a los ojos
humanos a consecuencia de una exposición de corta duración. Eviten de mirar fijo
el rayo láser así como evitarían cualquiera otra fuente de luminosidad intensa, por
ejemplo el sol. Además, eviten de dirigir el rayo láser hacia los ojos de un obser-
vador, también a través de superficies reflectantes como los espejos.
The laser scanner utilizes a low-power laser diode. Although staring directly at the
laser beam momentarily causes no known biological damage, avoid staring at the
beam as one would with any very strong light source, such as the sun. Avoid that the
laser beam hits the eye of an observer, even through reflective surfaces such as
mirrors, etc.
ATENCIÓN
La utilización de procedimientos o regulaciones diferentes de
aquellas describidas en la documentación puede causar una
exposición peligrosa a la luz láser visible.
CAUTION
The PowerScan™ PM8500 HandHeld Reader is not user-serviceable.
Opening the case of the unit can cause internal damage and will void
the warranty.
La utilización de procedimientos o regulaciones diferentes de aquellas
describidas en la documentación puede causar una exposición
peligrosa a la luz láser visible.
CAUTION
Regulatory Information
32 PowerScan™ M8500
WEEE Compliance
English
For information about the disposal of Waste Electrical and Electronic
Equipment (WEEE), please refer to the website at www.datalogic.com.
Italian
Per informazioni sullo smaltimento delle apparecchiature elettriche ed
elettroniche consultare il sito Web www.datalogic.com.
French
Pour toute information relative à l’élimination des déchets électroniques
(WEEE), veuillez consulter le site Internet www.datalogic.com.
German
Informationen zur Entsorgung von Elektro- und Elektronik- Altgeräten
(WEEE) erhalten Sie auf der Webseite www.datalogic.com.
Spanish
Si desea información acerca de los procedimientos para el desecho de los
residuos del equipo eléctrico y electrónico (WEEE), visite la página Web
www.datalogic.com.
Portuguese
Para informações sobre a disposição de Sucatagem de Equipamentos Eléc-
tricos e Eletrônicos (WEEE - Waste Electrical and Electronic Equip-
ment), consultar o site web www.datalogic.com.
Chinese
有关处理废弃电气电子设备 (WEEE) 的信息, 请参考 Datalogic
公司的网站: http://www.scanning.datalogic.com/。
Japanese
廃電気電子機器 (WEEE) の処理についての関連事項は Data-
logic のサイト www.scanning.datalogic.com, をご参照下さい。
Waste Electrical and Electronic Equipment (WEEE) Statement
Regulatory Information
Quick Reference Guide 33
Datalogic ADC Limited Factory Warranty
Datalogic warranties this product against defects in workmanship and materials,
for a period of 3 years from the date of shipment, provided that the product is
operated under normal and proper conditions.
Datalogic ADC (“Datalogic”) hardware products are warranted against defects in
material and workmanship under normal and proper use. The liability of Data-
logic under this warranty is limited to furnishing the labor and parts necessary to
remedy any defect covered by this warranty and restore the product to its normal
operating condition. Repair or replacement of product during the warranty does
not extend the original warranty term. Products are sold on the basis of specifica-
tions applicable at the time of manufacture and Datalogic has no obligation to
modify or update products once sold.
If Datalogic determines that a product has defects in material or workmanship,
Datalogic shall, at its sole option repair or replace the product without additional
charge for parts and labor, or credit or refund the defective products duly returned
to Datalogic. To perform repairs, Datalogic may use new or reconditioned parts,
components, subassemblies or products that have been tested as meeting applica-
ble specifications for equivalent new material and products. Customer will allow
Datalogic to scrap all parts removed from the repaired product. The warranty
period shall extend from the date of shipment from Datalogic for the duration
published by Datalogic for the product at the time of purchase (Warranty period).
Datalogic warrants repaired hardware devices against defects in workmanship and
materials on the repaired assembly for a 90 day period starting from the date of
shipment of the repaired product from Datalogic or until the expiration of the
original warranty period, whichever is longer. Datalogic does not guarantee, and it
is not responsible for, the maintenance of, damage to, or loss of configurations,
data, and applications on the repaired units and at its sole discretion can return
the units in the “factory default” configuration or with any software or firmware
update available at the time of the repair (other than the firmware or software
installed during the manufacture of the product). Customer accepts responsibility
to maintain a back up copy of its software and data.
Warranty Claims Process
In order to obtain service under the Factory Warranty, Customer must notify Dat-
alogic of the claimed defect before the expiration of the applicable Warranty
period and obtain from Datalogic a return authorization number (RMA) for
return of the product to a designated Datalogic service center. If Datalogic deter-
mines Customers claim is valid, Datalogic will repair or replace product without
additional charge for parts and labor. Customer shall be responsible for packaging
and shipping the product to the designated Datalogic service center, with shipping
charges prepaid. Datalogic shall pay for the return of the product to Customer if
the shipment is to a location within the country in which the Datalogic service
center is located. Customer shall be responsible for paying all shipping charges,
Regulatory Information
34 PowerScan™ M8500
duties, taxes, and any other charges for products returned to any other locations.
Failure to follow the applicable RMA policy, may result in a processing fee. Cus-
tomer shall be responsible for return shipment expenses for products which Data-
logic, at its sole discretion, determines are not defective or eligible for warranty
repair.
Warranty Exclusions
The Datalogic Factory Warranty shall not apply to:
(i) any product which has been damaged, modified, altered, repaired or
upgraded by other than Datalogic service personnel or its authorized repre-
sentatives;
(ii) any claimed defect, failure or damage which Datalogic determines was
caused by faulty operations, improper use, abuse, misuse, wear and tear,
negligence, improper storage or use of parts or accessories not approved or
supplied by Datalogic;
(iii) any claimed defect or damage caused by the use of product with any other
instrument, equipment or apparatus;
(iv) any claimed defect or damage caused by the failure to provide proper
maintenance, including but not limited to cleaning the upper window in
accordance with product manual;
(v) any defect or damage caused by natural or man-made disaster such as but
not limited to fire, water damage, floods, other natural disasters, vandalism
or abusive events that would cause internal and external component dam-
age or destruction of the whole unit, consumable items;
(vi) any damage or malfunctioning caused by non-restoring action as for exam-
ple firmware or software upgrades, software or hardware reconfigurations
etc.;
(vii) the replacement of upper window/cartridge due to scratching, stains or
other degradation and/or
(viii) any consumable or equivalent (e.g., cables, power supply, batteries, key-
pads, touch screen, triggers etc.).
No Assignment
Customer may not assign or otherwise transfer its rights or obligations under this
warranty except to a purchaser or transferee of product. No attempted assignment
or transfer in violation of this provision shall be valid or binding upon Datalogic.
Regulatory Information
Quick Reference Guide 35
DATALOGIC'S LIMITED WARRANTY IS IN LIEU OF ALL OTHER WAR-
RANTIES, EXPRESS OR IMPLIED, ORAL OR WRITTEN, STATUTORY
OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, ANY
IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PAR-
TICULAR PURPOSE, OR NONINFRINGEMENT. DATALOGIC SHALL
NOT BE LIABLE FOR ANY DAMAGES SUSTAINED BY CUSTOMER
ARISING FROM DELAYS IN THE REPLACEMENT OR REPAIR OF
PRODUCTS UNDER THE ABOVE. THE REMEDY SET FORTH IN THIS
WARRANTY STATEMENT IS THE CUSTOMER’S SOLE AND EXCLU-
SIVE REMEDY FOR WARRANTY CLAIMS. UNDER NO CIRCUM-
STANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY
THIRD PARTY FOR ANY LOST PROFITS, OR ANY INCIDENTAL, CON-
SEQUENTIAL IN-DIRECT, SPECIAL OR CONTINGENT DAMAGES
REGARDLESS OF WHETHER DATALOGIC HAD ADVANCE NOTICE
OF THE POSSIBILITY OF SUCH DAMAGES.
Risk of Loss
Customer shall bear risk of loss or damage for product in transit to Datalogic.
Datalogic shall assume risk of loss or damage for product in Datalogics possession.
In the absence of specific written instructions for the return of product to Cus-
tomer, Datalogic will select the carrier, but Datalogic shall not thereby assume any
liability in connection with the return shipment.
Numeric Table
36 PowerScan™ M8500
Numeric Table
01
ANFOGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKFHBHIK
AKCBPJCJGIIJCMCFGPOFMJLDJK
AEFBJLBGMHPKNIFGJCGBBDNHGK
AAPHBAJJDEBJCDJAGBDLGHNFHK
AFKEBJJPCPKMAJNAMBKKKCFJKK
DLDLLLDDDLLLLLLDLLDDDLDLLL
ANEPGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJALEHEEIK
AKCBPJCJGIIJCMCEHPLFIKNHNK
AEFBJLBGMHPKMKGPIEMNLKLEGK
AAPHBAJIDGFBMBLDDDNIEPNNFK
AEKEBJMNMOKOIOPNEFCOIJJLJK
DLDLLLDDLDDLLLLDDDLDDLDLLL
2
ANEOGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKEFGHIK
AKCBPJCJGIIJCMCEGMILJPPDNK
AEFBJLBGMHPKMKEKGKAMOGNEGK
AAPHBAJJDEFNLJHLIGJCCKKLDK
AELEBMKKGLEGCCHPLDIKICJLLK
DDLLLLDDDLDLLLLDLLLDDLDLLL
34
AMFPGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKECHEIK
AKCBPJCJGIIJCMCFGKLNLGILJK
AEFBJLBGMHPLNJDDOKGPBMIGGK
AAPHBAJIDCBNPBJGGNKINPEPFK
AGLEBMONMCIOAPCIABBMOFHJJK
DLLLLLDDLLLLLLLDLLLDDLDLDL
AMFOGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJALEAFHIK
AKCBPJCJGIIJCMCFHJIDKDKPJK
AEFBJLBGMHPLNJBGAEKOEAOGGK
AAPHBAJJDABBIJFONIOCLKDJDK
AGKEBJIKGHGGKDKKPHLIOOHJLK
DDDLLLDDDDLLLLLDDDLDDLDLDL
Numeric Table
Quick Reference Guide 37
56
AMEPGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKFAAEIK
AKCBPJCJGIIJCMCEGJNDOAMLNK
AEFBJLBGMHPLMLCPBCACOJIFGK
AAPHBAJIDCFJGLHNIKABJCDBBK
AHKEBJNIIGGECEIHHDDMMFLLIK
DDDLLLDDLLDLLLLDLLDDDLDLDL
AMEOGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJALFCCHIK
AKCBPJCJGIIJCMCEHKONPFOPNK
AEFBJLBGMHPLMLAKPMMDLFOFGK
AAPHBAJJDAFFBDLFDPELPHEHHK
AHLEBMLPCDIMIIAFIFJIMOLLKK
DLLLLLDDDDDLLLLDDDDDDLDLDL
7
ANFNGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKFCHFIK
AKCBPJCJGIIJCMCEHJLAGJEHJK
AEFBJLBGMHPKMMHJBODNLMGFGK
AAPHBAJIDFBCOHNDCJGDNMAPDK
AHKEBNOMACIOMCLCEECKCIFKLK
DDLLLLDDDDLLLLLDDLLDDLDLDL
89
ANFMGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJALFAFGIK
AKCBPJCJGIIJCMCEGKIOHMGDJK
AEFBJLBGMHPKMMFMPAPMOAAFGK
AAPHBAJJDHBOJPBLJMCJLJHJFK
AHLEBIILKHGGGODALCIOCDFKJK
DLDLLLDDLLLLLLLDLDLDDLDLDL
ANENGIFKDNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKEAAFIK
AKCBPJCJGIIJCMCFHKNODPAHNK
AEFBJLBGMHPKNOGFOGFAEJGGGK
AAPHBAJIDFFGHNDIMOMKJBHBHK
AGLEBINJEGGEOJBNDGAKAIJIKK
DLDLLLDDDDDLLLLDDLDDDLDLDL
Numeric Table
38 PowerScan™ M8500
NOTES
DECLARATION OF CONFORMITY
La presente dichiarazione di conformità è rilasciata sotto la responsabilità esclusiva di Datalogic ADC
Srl per:
This Declaration of Conformity is issued under the sole responsibility of Datalogic ADC Srl for:
Cette déclaration de conformité est établie sous la seule responsabilité de Datalogic Srl pour:
Diese Konformitätserklärung wird unter der alleinigen Verantwortung des Datalogic ADC Srl erteilt
für:
Esta declaración de conformidad se expide bajo la exclusiva responsabilidad de Datalogic ADC Srl
para:
Powerscan M83xx ; Cordless Barcode Reader
Powerscan M85xx ; Cordless Barcode Reader
sono conformi alla Direttiva del Consiglio Europeo sottoelencata:
are in conformity with the requirements of the European Council Directive listed below:
sont conformes aux spécifications de la Directive de l'Union Européenne ci-dessous:
der nachstehenden angeführten Direktive des Europäischen Rats entsprechen:
cumple con los requisitos de la Directiva del Consejo Europeo, según la lista siguiente:
1999/5/EC - R&TTE Directive
2011/65/EU – RoHS Directive
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
Datalogic ADC Srl, Via S. Vitalino, 13
Lippo di Calderara di Reno (BO) 40012 Italy
EC-054
Rev.: 4
Pag.: 1 di 1
e tutti i suoi modelli
and all its models
et tous ses modèles
und seine Modelle
y todos sus modelos
ETSI EN 301 489-3
V
1.4.1,
A
UGUST
2002 :
E
LECTROMAGNETIC
COMPATIBILITY
AND
R
ADIO
SPECTRUM
M
ATTERS
(ERM);
E
LECTROMAGNETIC
COMPATIBILITY
(EMC)
STANDARD
FOR
RADIO
EQUIPMENT
AND
SERVICES
; P
ART
3: S
PECIFIC
CONDITIONS
FOR
S
HORT
-R
ANGE
D
EVICES
(SRD)
OPERATING
ON
FREQUENCIES
BETWEEN
9
K
H
Z
AND
40GH
Z
EN 301 489-1
V
1.8.1, A
PRIL
2008
E
LECTROMAGNETIC
C
OMPATIBILITY
A
ND
R
ADIO
S
PECTRUM
M
ATTERS
(E
RM
);
E
LECTROMAGNETIC
C
OMPATIBILITY
(E
MC
) S
TANDARD
F
OR
R
ADIO
E
QUIPMENT
A
ND
S
ERVICES
; P
ART
1: C
OMMON
T
ECHNICAL
R
EQUIREMENTS
ETSI EN 300 220-2
V
2.1.2, J
UNE
2007 :
E
LECTROMAGNETIC
COMPATIBILITY
AND
R
ADIO
SPECTRUM
M
ATTERS
(ERM);
S
HORT
R
ANGE
D
EVICES
(SRD); R
ADIO
EQUIPMENT
TO
BE
USED
IN
THE
25MH
Z
TO
1000MH
Z
FREQUENCY
RANGE
WITH
POWER
LEVELS
RANGING
UP
TO
500
M
W; P
ART
2: H
ARMONIZED
EN
COVERING
ESSENTIAL
REQUIREMENTS
UNDER
ARTICLE
3.2
OF
THE
R&TTE D
IRECTIVE
EN 60950-1, A
PRIL
2006 +
A11:2009 + A1:2010 + A12:2011 :
I
NFORMATION
TECHNOLOGY
EQUIPMENT
- S
AFETY
-
P
ART
1 : G
ENERAL
R
EQUIREMENTS
EN 50581, S
EPTEMBER
2012:
T
ECHNICAL
D
OCUMENTATION
F
OR
T
HE
A
SSESSMENT
O
F
E
LECTRICAL
A
ND
E
LECTRONIC
P
RODUCTS
W
ITH
R
ESPECT
T
O
T
HE
R
ESTRICTION
O
F
H
AZARDOUS
S
UBSTANCES
Lippo di Calderara,
March29th , 2013
Ruggero Cacioppo
Quality & Reliability Manager - Europe
13
820058714 (Rev C) July 2013
www.datalogic.com
©2009-2013 Datalogic, Inc. • All rights reserved.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A.
in many countries, including the U.S.A. and the E.U.
Datalogic ADC, Inc.
959 Terry Street
|
Eugene
|
OR 97402
|
USA
Telephone: (1) 541-683-5700
|
Fax: (1) 541-345-7140
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic PowerScan PM8500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic PowerScan PM8500 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Datalogic PowerScan PM8500

Datalogic PowerScan PM8500 User Manual - English - 232 pages

Datalogic PowerScan PM8500 User Manual - Spanish - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info