535585
197
Zoom out
Zoom in
Previous page
1/232
Next page
Serial Configuration Strings
Product Reference Guide 189
a
= Hex values representing an ASCII character from
00
to
FE
enabling the device trigger.
b
= HEX values representing an ASCII character from
00
to
FE
inhibiting the device trigger.
RS-232
DESCRIPTION
STRING
Baud Rate 300
CD1
600
CD2
1200
CD3
2400
CD4
4800
CD5
9600
CD6
19200
CD7
38400
CD8
Parity none
CC0
even
CC1
odd
CC2
Data Bits 7
CA0
8
CA1
9
CA2
Stop Bits 1
CB0
2
CB1
Handshaking disable
CE0
RTS/CTS
CE1
XON/XOFF
CE2
RTS always On
CE3
ACK/NACK Protocol disable
ER0
enable
ER1
FIFO disable
EC0
enable
EC1
Inter-character Delay
(ms)
CK00 - CK99
RX Timeout
(100 ms)
CL00 - CL99
Serial Trigger Lock
disable
CR0
enable and select characters
CR1ab
197


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic PowerScan PM8500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic PowerScan PM8500 in the language / languages: English as an attachment in your email.

The manual is 6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Datalogic PowerScan PM8500

Datalogic PowerScan PM8500 User Manual - English - 44 pages

Datalogic PowerScan PM8500 User Manual - Spanish - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info