PowerScan™ PM8300-DK Configuration
12 PowerScan™ PM8300-DK 16-Key Reader
Using Multiple Readers with Same Cradle
If you want to use several readers associated with the same cradle, you must first
Bind the cradle with one of the readers (see previously described configuration
procedure).
Successive readers
can be associated with the same cradle by following the
configuration procedure substituting the Bind command with Join.
END of procedure.
PowerScan
PM8300-DK/STAR-MODEM™ Stand Alone
Setup
To configure a PowerScan™ PM8300-DK reader to communicate with STAR-
Modem™ in Stand Alone Mode, follow the "PowerScan™ PM8300-DK/BC-
80X0 Stand Alone Setup" procedure substituting steps 6 and 7 with those below:
END of procedure. YOUR READER IS NOW READY TO READ CODES.
7. Join
Ì$+RN1$-NÎ
The green LED on the PowerScan
PM8300-DK will blink: the reader is ready to
be positioned onto the cradle. Complete step 8.
All readers associated with the same cradle must have different
addresses.
CAUTION
6. STAR-Modem™ Address
ÌRSRÎ
Read the code above and the four-digit address of the STAR-Modem™.
7. Exit and Save Configuration
Ì$-?Î
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic PowerScan PM8300-DK at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic PowerScan PM8300-DK in the language / languages: English as an attachment in your email.

The manual is 1,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info