535569
15
Zoom out
Zoom in
Previous page
1/24
Next page
How to Scan
Quick Reference Guide 13
Variable Length Control, Length One = 1, Length two = 80, Char-
acter Correlation = disabled, Stitching = enabled.
Interleaved 2 of5—ZeroPattern and Check Character Calcula-
tion = disabled, Check Character Transmission = enabled, Mini-
mum Reads = 1, Decoding Levels and Aggressiveness = 3, Variable
Length Control, Length One = 12, Length Two = 100, Character
Correlation and Stitching = disabled.
Disabled Symbologies
GS1 DataBar (Omnidirectional, Expanded and Limited), GTIN format-
ting, Pharmacode 39, Codabar, Code 93, Code 11, Standard 2 of 5.
How to Scan
When the trigger is pressed, the reader projects a red, horizontal illumi-
nating beam. This beam will remain on until the trigger is released, a
barcode is read, or until a time-out
1
period expires.
Linear Barcodes —
To scan a linear barcode, center the illumination
beam over the barcode as shown in
Figure 3. The reader must see across
the width of all of the bars. Move the reader further away from the bar-
code to increase the scanning coverage area, and closer in to read very
small barcodes.
1. Reference the Product Reference Guide (PRG) for more information about the aiming
beam time-out period.
NOTE
If the surface being scanned is highly reflective
(e.g., laminated), it may be necessary to tilt the item
or the reader slightly (15° to 18°) to prevent
unwanted reflection.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic PowerScan PD7100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic PowerScan PD7100 in the language / languages: English as an attachment in your email.

The manual is 1,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Datalogic PowerScan PD7100

Datalogic PowerScan PD7100 User Manual - Spanish - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info