535550
16
Zoom out
Zoom in
Previous page
1/346
Next page
Introduction
6
PowerScan™ PD9530/PBT9500/PM9500
charge / charge cycles before needing replacement. This number is higher if
partial discharging / recharging is adhered to rather than full / deep dis-
charging,
The typical manufacturer advertised useful life
of LI batteries is one to three
years, depending on usage and number of charges, etc., after which they
should be removed from service, especially in mission critical applications.
Do not continue to use a battery that is showing excessive loss of capacity, it
should be properly recycled / disposed of and replaced. For most applica-
tions, batteries should be replaced after one year of service to maintain cus-
tomer satisfaction and mini
mi
ze safety concerns.
Collect and recycle waste batteries separately from the device in compliance
with Euro
pean Directive 2006/66/EC, 2011/65/EU, 2002/96/EC and 2012/
19/EU and subsequent modifications, US and China regulatory and others
laws and regulations about the environment.
Programming the Reader
Configuration Methods
Programming Bar Codes
The reader is factory-configured with a standard set of default features.
After scanning the interface bar code, you can select other options and cus-
tomize your reader through use of the instructions and programming bar
code
labels available in the corresponding features section for your inter-
face. Customizable settings for many features are found in "Configuration
Parameters" st
ar
ting on page 21.
Some programming labels, like "Restore Custom Defaults" on pa
ge 18,
require only the scan of the single label to enact the change. Most, however,
require the reader to be placed in Programming Mode prio
r to scanning
them. Scan an ENTER/EXIT bar code once to enter Programming Mode. Once
the reader is in Programming Mode, scan a number of parameter settings
before scanning the ENTER/EXIT bar code a second time, which will then
accept your changes, exit Programming Mode and return the reader to nor-
mal operation.
There are some exceptions to the typical programming sequence
described above. Please read the description and setting instructions
carefully when configuring each programmable feature.
Datalogic Aladdin™
Datalogic Aladdin™ is a multi-platform utility program providing a quick and
user-friendly configuration method via the RS-232/USB-COM interface.
Aladdin allows you to program the reader by selecting configuration com-
mands through a user-friendly graphical interface running on a PC. These
co
mm
ands are sent to the reader over the selected communication interface,
or they can be printed as bar codes to be scanned. Aladdin also facilitates
image capturing.
In addition, Aladdin makes it easy to upgrade the handheld’s firmware, to
attain the be
nefits of new reader features. Reference the Datalogic Aladdin™
Online Help for more details.
Aladdin is available for download free of charg
e on the Datalogic website.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic PowerScan PBT9500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic PowerScan PBT9500 in the language / languages: English as an attachment in your email.

The manual is 9,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Datalogic PowerScan PBT9500

Datalogic PowerScan PBT9500 User Manual - English - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info