PowerScan™ M8300 Configuration
8PowerScan M8300
POWERSCAN
M8300 CONFIGURATION
POWERSCAN
M8300/BC-80X0 POINT-TO-POINT SETUP
A rapid configuration procedure has been devised for point-to-point applications
where a single
reader is associated exclusively with its own BC-80X0 base station and
where it is not necessary to set the Date and Time parameters.
A special pre-printed bind-address label provided in the BC-80X0 base station
package can be used to bind the PowerScan
M8300 reader to the base station with
the address coded on the label. The address is also written numerically on the label to
be easily recognized. Valid addresses are in the range from 0000 to 1999. Make sure
that all cradles used in the same area have different addresses.
To rapidly configure your point-to-point application:
END of procedure. YOUR READER IS NOW READY TO READ CODES.
1. Apply the bind-address label onto the BC-80X0 base station as indicated in
the BC-80X0 Quick Reference Manual.
2. When the BC-80X0 cradle is connected and powered, read the
Bind-Address label to pair the PowerScan
M8300 to the BC-80X0 cradle.
The green LED on the PowerScan
M8300 will blink: the reader is ready to be
positioned onto the cradle.
3. Firmly position the reader onto the cradle within 10 seconds, a beep will be
emitted, signaling that the BC-80X0 cradle has been paired to the
PowerScan
M8300, and the green LED on the reader will go off.
If it ever becomes necessary to
change the reader, just read the
bind-address label applied to the
cradle and position the new
reader onto the cradle.
Do not use multiple readers with
this configuration method.
4. Configure the BC-80X0 cradle, refer to the “BC-80X0 Quick Reference”.
Green LED
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic PowerScan M8300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic PowerScan M8300 in the language / languages: English as an attachment in your email.

The manual is 1,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info