198
Magellan
TM
3300HSi
I 2 of 5
Check character must be included in label data.
Label length including check characters and excluding prefix characters must meet requirements imposed by
the main scanner's fixed or variable label length control for this symbology type.
Prefix must be an ASCII character ']I1' (other prefixes specify different check character properties which are
not supported).
Example: ']I10123456789'.
Code 128 / EAN128
Prefix must be either ASCII characters ']C0', ']C1' or ']C2'.
Label length excluding prefix character must meet requirements imposed by the main scanner's fixed or vari-
able label length control for this symbology type.
If EAN-128 Symbology is Enabled and prefix is ']C1', label will be identified as an EAN128 otherwise it is
identified as a Code 128.
A prefix of ']C0' designates that no function code is present in the 1st or 2nd character position.
A prefix of ']C2' designates that a function code 1 is present in the 2nd character.
Example : ']C0Code_128.Test'.
PDF417
Prefix must be an ASCII characters ']L0'.
Label length excluding prefix character cannot exceed 300 characters. In addition to this, label length exclud-
ing prefix character must meet requirements imposed by the main scanner’s fixed or variable label length con-
trol for this symbology type.
Example : ']L0pdf_test_label'.
“Unknown” AIM ID (an AIM ID which is not specified above)
If a label is received that does not have an AIM ID as specified above, and the first three label characters qualify as
follows...
The first character is a ‘]’
The second character is a capital or small letter
The third character is a digit
...then the label type is set to GENERIC_DATA and the “unknown” AIM ID is left-appended to the beginning of
the label data.
206


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic Magellan 3300HSi at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic Magellan 3300HSi in the language / languages: English as an attachment in your email.

The manual is 3,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Datalogic Magellan 3300HSi

Datalogic Magellan 3300HSi User Manual - English - 28 pages

Datalogic Magellan 3300HSi User Manual - Spanish - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info