RS-232 Interface Features — cont.
Retry on ACK NAK Timeout
Enables/disables retry after the configurable ACK NAK Timeout Value (set in the following
feature) has expired.
START / END
PROGRAMMING BARCODES
Disable Retry on ACK NAK Timeout
Enable Retry on ACK NAK Timeout
DEFAULT
ACK NAK Timeout Value
START / END
PROGRAMMING BARCODES
This item specifies the time the scanner
will wait for an ACK character from the host following a label trans-
mission.
000 = Infinite timeout
001 - 075 = Timeout in 200-millis
econd increments
To configure this feature, scan the “START/END” barcod
e above to place the unit in Programming Mode,
then the “Set ACK NAK Timeout Value,” followed by the three digits (zero padded) from the Alphanumeric
table in
Appendix C, Alpha-Numeric Pad representing your desired value. Exit programming mode by again
scanning the “START/END” barcode above.
DEFAULT SETTING FOR THIS FEATURE: 001 (200 msec)
Set ACK NAK Timeout Value
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic Magellan 1100i at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic Magellan 1100i in the language / languages: English as an attachment in your email.

The manual is 2,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Datalogic Magellan 1100i

Datalogic Magellan 1100i User Manual - English, German, French, Italian, Portuguese, Spanish - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info