Scanner Direct IO Commands
24
Datalogicâ„¢ JavaPOS Device Services
Scanner Direct IO Commands
The scanner supports a number of Direct IO commands that allow access to
the commands available on the interface which are not directly supported
by UPOS. Applications may utilize the Direct IO commands by accessing the
Direct IO Method (see the Unified POS Retail Peripheral Architecture, version 1.13
for details) with the appropriate arguments, as detailed below. For a com-
plete list of commands and implementation details, see DR90000351, Data-
logic UPOS DirectIO Commands (available at www.datalogic.com).
Table 3
Scanner Command Cmd int[] data Object object
Reset 1 None None
Beeper enable 2 None or Input: Config String
Output: Status string
Beeper disable 3 None or Input: Config String Output: Status string
Configure scanner 4 None or Input: Config String
Input: 9 byte config string
Output: Status string
Report configuration 5 None or Input: Config String Output: 9 byte config string
Configure 2-label flags 6 None or Input: Config String
Input: 8 byte 2-label config string
Output: Status string
Report 2-label config 7 None or Input: Config String
Output: 8 byte 2-label config
string
Report Information 8 None or Input: Config String
Output: Variable length string
Report Health 9 None or Input: Config String Output: Variable length string
Report Statistics 10 None or Input: Config String Output: Variable length string
. OEM USB Direct IO Scanner Commands
Table 4. RS-232 Standard Scanner Direct IO Commands
Scanner Command Cmd int[] data Object object
Reset 1 None None
Beep 11 None None
Table 5
Scanner Command Cmd int[] data Object object
Hard Reset 21 None None
Scale Monitor 26 Output: Status Output: None
Scale Status 27 None
Output: Scale status
Display Status 28 None Output: Display status
Soft Power Down 29 None None
. RS-232 Single Cable Direct IO Scanner/Scale Commands
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic JAVA POS Device Services at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic JAVA POS Device Services in the language / languages: English as an attachment in your email.

The manual is 2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info