654643
11
Zoom out
Zoom in
Previous page
1/104
Next page
11
User Instructions
GB
Option 1 - Enable or disable A/B programming (Option 41 set to 5/2)
This enables or disables the A/B programming option. Press
+ until Option 1 is displayed, use Λ and V to select required
setting.
Setting 0
Disabled, unit operates as 5/2 or 24 hour product depending on
installer settings (factory setting)
Setting 1 Enabled: activates A/B programming
Option 3 - Calendar clock rules
This establishes the rules that the automatic calendar clock
follows to calculate changes between summer and winter
time. Press + until Option 3 is displayed, use Λ and V to select
required setting.
Setting 0 Disabled.
Setting 1
Manual: user must change using + to advance and - to retard
displayed time.
Setting 2 European rules. (Factory Setting)
Setting 3 USA rules (2007 onwards)
Setting 4 USA rules (pre-2007)
Option 4 - Time zone off set
This feature allows the time zone to be established and
corrects time display. Press + until Option 4 is displayed, use Λ
and V to select required setting
Setting 0 UK models: this feature should be left at the factory setting of 0.
Setting 1
Central European time models: this feature should be left at the
factory setting of +1:00.
-12 Hours +14 Hours
Rest of World: use Λ and V keys to select off set from Universal time (GMT) for the
location in which the thermostat is being installed.
Option 10 - Frost/ thermostat mode setting
This feature allows the default frost/thermostat mode
temperature to be set. Press + until Option 10 is displayed, use
Λ and V to select required setting.
5-40°C - Factory setting is 8°C, but can be changed to any value between 5 -40°C.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Danfoss TP5001M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Danfoss TP5001M in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 2,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Danfoss TP5001M

Danfoss TP5001M Installation Guide - English, German, Dutch, Danish, French, Italian, Spanish - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info