AIR CONDITIONER OPERATIONS AND PERFORMANCE
A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it is
restarted immediately after operation.
Select the position for the outdoor unit where it will not be subject to snow drifts, accumulation of leaves
or other seasonal debris. It is important that the air flow for the outdoor unit is not impeded as this will result in
reducing heating or cooling performance. During the heating mode (cooling only type without) and at sub-zero
temperatures, the water drained off the outdoor unit as a result of the automatic defrost may accumulate and
freeze. It is important that adequate drainage or a soak way is provided.
Power failure during operation will stop the unit completely.
The OPERATION lamp on the indoor unit will start flashing when power is restored.
To restart operation, push the ON/OFF button on the remote controller.
Lighting or a car wireless telephone operating nearby may cause the unit to malfunction. Disconnect the unit
with the power and then connect the unit with the power again. Push the ON/OFF button on the remote
controller to restart it.
For proper performance, run the air conditioner under the following temperature conditions:
Heating characteristics preheating operation
The air conditioner will not deliver warm air immediately after it is started. Warm air flows out after
approximately 5 minutes when the indoor heat exchanger warms up.
Warm air control
When the room temperature reaches the set temperature, the fan speed is automatically reduced to
prevent a cold draft. At this time, the outdoor unit will stop.
Defrosting
If the outdoor unit is frosted during heating operation, defrosting is started automatically (for approximately
5 to 10 minutes) to maintain the heating effect, and the PRE.-DEF. lamp is on.
The fans in both the indoor and outdoor units stop during the defrost operation.
During defrost operation, defrosted water is drained from the bottom plate of the outdoor unit.
Heating capacity
In the heating operation, heat is absorbed from outdoor and released into the room. that is so-called heat
pump system. When the outdoor temperature is too low, you are recommended to use another heating
apparatus in combination with the air conditioner.
Three-minute protection feature
Consideration for accumulated snow
Power failure
Air conditioner operating conditions
This will protect the machine. (cooling only type without)
If air conditioner is used outside of the above conditions, safety protection features may come into operation.
¡£
Outdoor temperature: 18 to 43 C
¡£
Outdoor temperature: 11 to 43 C
¡£
Outdoor temperature: -7 to 24 C
¡£
Room temperature: 17 to 32 C
¡£
Room temperature: 17 to 32 C
Room temperature: 0 to 27 C
Heating
operation
Cooling
operation
Dry
operation
Room relative humidity less than 80%. If the air conditioner operates in excess
of this figure, the surface of the air conditioner may attract condensation.
CAUTION
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daitsu ASD9T2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daitsu ASD9T2 in the language / languages: English as an attachment in your email.

The manual is 0,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daitsu ASD9T2

Daitsu ASD9T2 User Manual - Portuguese - 13 pages

Daitsu ASD9T2 User Manual - Spanish - 13 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info