730615
30
Zoom out
Zoom in
Previous page
1/92
Next page
25
Error codes and protection code:
E1- Room temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E2- Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E3- Condenser temperature sensor error-
Unplug the unit and plug it back in. If error
repeats, call for service (on some models).
E4- Display panel communication error-
Unplug the unit and plug it back in.
If error repeats, call for service.
P1- Bottom tray is full - Connect the drain
hose and drain the collected water away.
If protection repeats, call for service.
9. FOLLOW ME/TEMP SENSING feature (optional)
NOTE:This feature can be activated from the
remote control ONLY. The remote control
servesas a remote thermostat allowing for the
precise temperature control at its location.
To activate the Follow Me/Temp Sensing
feature, point the remote control towards
the unit and press the Follow Me/Temp
Sensing button. The remote display is actual
temperature at its location. The remote control
will send this signal to the air conditioner every
3 minutes interval until press the Follow
Me/Temp Sensing button again. If the unit
does not receive the Follow Me/Temp Sensing
signal during any 7 minutes interval, the unit
will beep to indicate the Follow Me/Temp
Sensing mode has ended.
10. POWER MANAGEMENT feature
When the ambient temperature is lower (Cooling
mode) or higher (Heating mode) than the setting
temperature for a period of time, the unit will
be automatically operate power management
feature. The power management indicator light
When the ambient temperature is higher (Cooling
mode) or lower (Heating mode) than the setting
temperature, the unit will be automatically quit the
power management feature. The power
management indicator light turns dark and the
compressor and (or) fan motor run.
Operating instructions
COOL operation
- Press the “MODE” button until the “COOL” indicator
light comes on.
- Press the ADJUST buttons “+” or “ - “ to select your
desired room temperature. The temperature can be
set within a range of 17OC-30OC/62OF-88OF (or
86OF).
- Press the “FAN SPEED” button to choose the fan
speed.
HEAT operation (cooling only models without)
Press the “MODE” button until the “HEAT”
indicator light comes on.
- Press the ADJUST buttons “+” or “ - “ to
select your desired room temperature. The
temperature can be set within a range of
17ºC-30ºC/62ºF-88ºF (or 86ºF).
- Press the “FAN SPEED” button to choose
the fan speed. For some models, the fan
speed can not be adjusted under HEAT
mode.
DRY operation
Press the “MODE” button until the “DRY” indicator
light comes on.
- Under this mode, you cannot select a fan speed or
adjust the temperature. The fan motor operates at
LOW speed.
- Keep windows and doors closed for the best
dehumidifying effect.
- Do not put the duct to window.
AUTO operation
When you set the air conditioner in AUTO
mode, it will automatically select cooling,
heating(cooling only models without), or fan only
operation depending on what temperature you have
selected and the room temperature.
- The air conditioner will control room temperature
automatically round the temperature point set by
you.
- Under AUTO mode, you can not select the fan
speed.
NOTE: Under AUTO mode, both the AUTO mode
and the actual operation mode indicator lights
illuminate.
FAN operation
Press the “MODE” button until the “FAN “
indicator light comes on.
- Press the “FAN SPEED” button to choose
the fan speed. The temperature cannot be
adjusted.
- Do not put the duct to window.
TIMER operation
When the unit is on, press the Timer button will
initiate the Auto-off stop program, the TIMER OFF
indicator light illuminates. Press the UP or down
button to select the desired time. Press the TIMER
button again within 5 seconds, the Auto-on start
program is initiated. And the TIMER ON indicator
light illuminates. Press the up or down button to
select the desired Auto-on start time.
OPERATING INSTRUCTIONS
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daitsu APD-9CR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daitsu APD-9CR in the language / languages: English, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info