English
If this happens Check How to resolve
Crackling, buzzing, and
zzes sounds are audible
during operation.
Is the UNIT1 set securely?
Securely set it.
Page 18.
Has dust accumulated on the ionized wires of the
ionizing frame?
Clean it.
Page 33, 34.
A hissing sound heard from UNIT2 during operation.
There is nothing wrong with the unit.
-
There is no sound of
streamer discharge.
Are the needles inside UNIT2 clean?
Clean the needles.
Odor is coming from the
air outlet.
Is a large amount of odor being generated
temporarily? (Many people smoking or grilling meat.)
If operated, the odor will gradually go away.
Have you moved the main unit to another room?
Odor from the original room may smell.
Let the unit run for a while.
Are the pre- lter, pleated lter, UNIT1 and/or
humidifying lter dirty?
Clean it.
Page 29-36.
Are odors constantly being generated in the room (i.e.,
paint, new furniture, wall paper, sprays, cosmetics,
chemicals, etc.)?
Ventilate the room or let the unit run with air ow
promoted in the room.
A very small amount of ozone is generated by the
unit and may cause a slight odor at the air outlet.
However, since the amount of ozone is minute, it will
not cause any health problem.
-
The “UNIT1” lamp does
not go out or immediately
lights again, despite
having cleaned that UNIT1
(plasma ionizer).
Is the UNIT1 set securely?
Securely set it.
Page 18.
Are not droplets left in the opposing pole plates or
other places?
Completely dry UNIT1 after cleaning it.
Are not bits of lint left in the UNIT1? Remove all lint.
Was UNIT1 inadequately rinsed after cleaning with a
cleaner?
Remove any remaining cleaner.
Page 33, 34.
Are not the ionized wires cut?
Check the ionized wires.
Page 34.
If broken, they need replacing, therefore contact the
service shop.
Humidity does not rise.
Is the room too big?
Use the unit in an appropriately sized room.
Is indoor temperature low with the walls and oor dry?
Humidity does not readily rise if the indoor temperature
is low, and the walls and oor are dry. Watch the
situation for 1 - 2 weeks to see if humidity rises.
Is air ow set to a low rate?
Set “CONT” for the humidify setting and increase the
air ow rate setting.
If the problem cannot be corrected after taking the above action, contact the service shop.
01_EN_3P234570-1D.indd 4201_EN_3P234570-1D.indd 42 2/10/2010 11:41:31 AM2/10/2010 11:41:31 AM
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin MCK75JVM-K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin MCK75JVM-K in the language / languages: English as an attachment in your email.

The manual is 3,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin MCK75JVM-K

Daikin MCK75JVM-K User Manual - German - 46 pages

Daikin MCK75JVM-K User Manual - Dutch - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info