1
Remove the front panel.
Page 29.
2
Remove the water tank.
Page 29.
3
Remove the UNIT1.
Holding the UNIT1 by the handle, pull the UNIT1 upwards
and out of the unit.
UNIT1
Handle
(1)
Pull
(2)
Up
4
Remove the opposite pole plates on the
backside of UNIT1.
Pinching together the white and green knobs (2 sets on
left and right), lift the opposite pole plates up and out.
Knob
(white)
Knob
(green)
Wear rubber
gloves.
There are
ionized wires inside,
therefore be careful
that they do not catch
on anything.
Opposing pole
plates
Ionizing frame
Pinching the sets of
knobs on the left and right at
the same time makes it easier
to remove the opposite
pole plates.
Ionized wire
Attach
1
Attach the opposing pole plates.
(1) Fit the opposite pole plates over the knobs (2 sets on left
and right) on the ionizing frame.
The opposite pole plates have no required right and left
direction and can be attached either side of ionizing
frame. Attach them so that the arrow is visible.
Knob (white)
Arrow
Ionizing frame
Wear rubber
gloves.
(2) Insert securely until it clicks.
(3) Attach another side of the opposing pole plate.
2
Restore the UNIT1
Page 31.
, pre- lter,
water tank and front panel.
Page 29.
UNIT1 (Plasma ionizer) removing and attaching
Wear rubber gloves to remove and attach the opposite pole plates. Hands can be cut on the opposite pole plates and ionized wires.
01_EN_3P234570-1D.indd 3201_EN_3P234570-1D.indd 32 2/10/2010 11:41:16 AM2/10/2010 11:41:16 AM
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin MCK75JVM-K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin MCK75JVM-K in the language / languages: English as an attachment in your email.

The manual is 3,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin MCK75JVM-K

Daikin MCK75JVM-K User Manual - German - 46 pages

Daikin MCK75JVM-K User Manual - Dutch - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info