Settings of Modes within ECONO MODE
Monitoring
ON*
Monitoring
OFF
Setting procedures Remote controller Unit
1.
Hold down on the unit for about 5 seconds and when a short beep sounds, press on the
remote controller while pressing
on the unit.
• This setting change can be performed when the unit is on or off.
2. Release both buttons when a short beep sounds.
• The FAN lamp (Quiet) and ECONO MODE lamp will light up after blinking for about 5 seconds.
The ECONO MODE lamp will light up or blink depending on the ON/OFF status of Monitoring mode.
3. Press
on the unit to change the setting.
• Each press turns the ECONO MODE lamp ON or OFF.
(The FAN lamp
(Quiet) will remain lit up.)
To turn Monitoring mode ON
Turn on the ECONO MODE lamp.
Setting at time
of purchase
ON
OFF
To turn Monitoring mode OFF
Turn off the ECONO MODE lamp.
• Setting is indicated using the ECONO MODE lamp. If the ECONO MODE lamp does not change, unplug the unit, wait at
least 5 seconds, then re-insert the power supply plug and repeat the above procedure from the beginning.
4. Press
on the remote controller after selecting the new setting.
• A short beep sounds and the FAN lamp (Quiet) will blink. When Monitoring mode is turned ON, the ECONO MODE
lamp also blinks.
Unplug the unit while the lamp is blinking, wait at least 5 seconds, and then re-insert the power supply plug.
Setting is now complete.
• If this procedure is not performed, the unit will not return to regular operation mode.
Note