Useful Functions
MODE Usage and Function
AUTO FAN
Automatic airflow rate adjustment
FAN setting (Quiet, Low, Standard, High) is automatically adjusted according to the degree of air
impurity and humidity (when the Humidifying operation is active).
Purifying capacity increases as airow rate rises.
Press to select the humidity level.
Degree of air impurity corresponds to the volume of dust and the intensity of odours in the ambient air.
ECONO
Saving energy
In Power saving mode within ECONO MODE, the FAN setting automatically switches between Quiet
and Low only. Power consumption (*1) and operating sounds are reduced.
If the air is clean and the set humidity level has been achieved (when the Humidifying operation is
active), after a short while, Monitoring mode automatically activates.
Recommended for use during sleep hours.
*1 By comparison to AUTO FAN MODE (approx. 10.6Wh), power consumption in ECONO MODE (approx.
6.9Wh) is approx. 3.7Wh lower.
Test conditions: operation in 10m
2
area over 1 hour. Assuming 1 cigarette was smoked immediately
after the unit was turned on.
Power saving mode
FAN setting switches
automatically between
Quiet and Low.
If the air is clean and the set
humidity level has been
achieved, after a short while...
Monitoring mode
The fan starts and stops periodically. Dust,
odours, and the humidity level are
monitored.
The following functions are turned off, further
reducing power consumption.
Streamer
OFF OFF
Humidifying
Active plasma ion
OFF
If the humidity level falls, or
dust or odours are
detected...
*2 The humidier ON/OFF lamp remains lit up.
(*2)
As the FAN setting is limited to Quiet and Low, air purifying and humidifying capacity is reduced.
As air is not drawn in when the fan has stopped, the dust/PM2.5 sensor, odour sensor, and humidity sensor
reduce in sensitivity. To prevent this reduction in sensitivity, turn Monitoring mode OFF.
Page 22
FAN setting is adjusted automatically. Airow cannot be adjusted manually.
Press
to select the humidity level.
ANTI-
POLLEN
Reducing pollen levels
A gentle air current is created by switching every 5 minutes between the FAN setting Standard and
Low so that pollen can be drawn in and caught before it reaches the oor.
FAN setting is adjusted automatically. Airow cannot be adjusted manually.
Press
to select the humidity level.
MOIST
Combating dry throat and skin
Humidity is automatically adjusted to be gentle on the throat and skin.
As humidity is kept relatively high, if the temperature
difference between outdoors and indoors is large,
condensation may result.
FAN setting is adjusted automatically. Airow cannot be
adjusted manually.
Humidity level is set automatically. Humidity level cannot
be selected.
If
is pressed when MOIST MODE is active, MOIST
MODE stops and AUTO FAN MODE is activated.
Humidity level will be the level selected previously.
Room conditions and target humidity
Target humidity (%)
Room temperature (°C)
70%
40%
60
50
100
90
80
70
60
50
40
30
0
10 15 20 25 30
01_EN_3P595628-1B.indd 18 2020/04/17 15:49:05
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin MCK55WVM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin MCK55WVM in the language / languages: English as an attachment in your email.

The manual is 8,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin MCK55WVM

Daikin MCK55WVM User Manual - German - 40 pages

Daikin MCK55WVM User Manual - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info