Troubleshooting
Before making an inquiry or a request for repair, please check the following.
If the problem persists, contact the place of purchase.
In the event of malfunction during operation
If the indicator lamps light up abnormally, or become inoperable, due to a lightning strike etc., remove the power supply plug, wait
at least 5 seconds then re-insert the power supply plug and turn the unit on again.
Not a problem
This case is not a problem.
Check
Please check again before requesting repairs.
Unit does not respond
Phenomenon Check points
No response even if
on the
remote controller is pressed
Has the battery run out?
¼
Replace the battery.
Page 11
Is a button on a remote controller for a TV, VCR or other appliance,
stuck pressed down?
¼
If a button on another remote controller is stuck pressed down because
it is pressed against a remote controller rack etc., it may interfere with
reception.
Is there a device in the room that redirects remote controller signals?
¼
Some appliances such as TV speakers are equipped with these devices.
If there is such a device in the room, the signals it emits may interfere
with signals from the remote controller, preventing reception.
To protect the system, the unit may stop operating after a sudden voltage
uctuation.
If operating at the time of the voltage uctuation, operation will resume
automatically once voltage returns to normal.
Voltage range protection: 180V-264V
Unit will not operate
Is the streamer unit cover attached?
If it is not attached, the safety switch will engage, and the unit cannot operate.
¼
Install the streamer unit cover properly and attempt operation again.
Page 21
Sounds can be heard
Phenomenon Check points
Hissing sound during operation A hissing sound is generated when there is streamer discharge during
streamer operation. Depending on usage conditions, the sound may lessen
or change to a crackling, whirring or guzzling sound. However, this is
normal.
If the sounds are an issue, move the unit to a different location.
Page 16
Whistling and uttering sound during
operation
Is there a buildup of dust on the pre-lter?
¼
Clean this part.
Page 19
Is the dust collection lter clogged up?
¼
Depending on usage conditions, the dust collection filter may become
clogged up, shortening its service life.
Page 9
Replace the dust collection filter.
Page 20
Operating sound is loud Is the dust collection lter properly attached?
¼
If it is not properly attached, operating sounds may become louder.
Page 20
Indicator lamps
Phenomenon Check points
Indicator lamps do not light up
Indicator lamps turn off about 10
seconds after the unit is turned on
Is indicator lamp brightness set to OFF?
¼
If indicator lamp brightness is set to OFF, all lamps except the ON/OFF
lamp will remain off.
¼
If indicator lamp brightness is set to OFF, after the unit is turned on, the
brightness of the indicator lamps will be DIM for about 10 seconds and
then turn OFF.
Page 15
Troubleshooting
01_EN_3P595629-1B.indd 25 2020/04/17 16:01:58
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin MC55WVM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin MC55WVM in the language / languages: English as an attachment in your email.

The manual is 5,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin MC55WVM

Daikin MC55WVM User Manual - German - 30 pages

Daikin MC55WVM User Manual - Dutch - 30 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info