25
Multi Connection
A multi system has one outdoor unit connected to multiple indoor units.
Selecting the operation mode
When the priority room setting is active
but the set unit is not operating or when
the priority room setting is inactive
When more than one indoor unit is operating, priority is given to
the rst unit that was turned on.
In this case, set the units that are turned on later to the same
operation mode as the rst unit.
Otherwise, they will enter the standby state, and the OPERATION
lamp will blink; this does not indicate malfunction.
NOTE
Notes on operation mode for a multi system
COOL, DRY and FAN operation may be used at the same time.
AUTO operation automatically selects COOL operation or HEAT operation based on the indoor temperature.
Therefore, AUTO operation is available when selecting the same operation mode as that of the room with the rst unit to be turned on.
CAUTION
Normally, the operation mode in the room where the unit is rst started is given priority, but the following situations are exceptions to this rule.
If the operation mode of the rst room is FAN operation, then using HEAT operation in any room after this will give priority to HEAT operation.
In this situation, the indoor unit operating in FAN mode will switch to standby, and the OPERATION lamp will blink.
With the priority room setting active
Refer to “Priority room setting on the next page.
NIGHT QUIET operation (Available only for COOL operation)
NIGHT QUIET operation requires initial programming during installation. Please consult your retailer or dealer for assistance.
NIGHT QUIET operation reduces the operation noise of the outdoor unit during the night-time hours to prevent annoyance to neighbors.
NIGHT QUIET operation is activated when the temperature drops 10.8°F (6°C) or more below the highest temperature recorded that day.
When the temperature difference between the current outdoor temperature and the maximum outdoor temperature becomes less than
7.2°F (4°C), this function will be canceled.
NIGHT QUIET operation slightly reduces the cooling efciency of the unit.
OUTDOOR UNIT QUIET operation
Refer to “OUTDOOR UNIT QUIET Operation.
Page 16
When the priority room setting is active but the set unit is not operating or when the
priority room setting is inactive
When using the OUTDOOR UNIT QUIET operation feature with a multi system, set all indoor units to OUTDOOR UNIT
QUIET operation using their remote controllers.
When canceling OUTDOOR UNIT QUIET operation, simply cancel the mode on one of the operating indoor units using their
remote controller.
However OUTDOOR UNIT QUIET operation will remain displayed on the remote controllers for the other rooms.
We recommend you cancel operation in all rooms using their remote controllers.
With the priority room setting active
Refer to “Priority room setting on the next page.
Room A Room B
Room C Room D
Outdoor unit
Note for Multi System
01_EN_3P379751-5C.indd 25 11/9/2015 13:35:45
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin FVXS09NVJU FVXS12NVJU FVXS15NVJU FVXS18NVJU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin FVXS09NVJU FVXS12NVJU FVXS15NVJU FVXS18NVJU in the language / languages: English, French, Spanish as an attachment in your email.

The manual is 11,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info